dc.description.abstract為了取得電極間的距離進而控制電鍍的程序因此進行了電鍍時的溶液電阻量測研究,我們發現使用頻率為90kHz或是更高頻率之交流測試訊號可以使得電雙層電容與極化電阻相對於存在於電極間之溶液電阻而言變得可以忽略。因此,溶液阻抗的量測變得可行。 當包覆在粗的塑脂絕緣鞘中的細電極在近距離面對導電平板,因為狹窄通道效應會限制了有效的導通區域為電極下的截面積,因此有效的溶液電阻與間距會呈現一負相關。對125uM直徑的電極而言,間距在150μm以下都會有通道效應。藉此關係可以進行精密的導體表面輪廓掃描。 當電極與平板陰極的距離大於150uM以上,或者當析出之針狀物高度大於這個值以後,容液電阻值與電極間距的關係不再明顯,而不像導線中帶電粒子有集中式的通道而呈現與長度有正比的關係。因而無法用溶液電阻值來反映電極間距。zh_TW
dc.description.abstractStudying the measurement of solution resistance in electro-plating so as to derive the information on the distance between electrodes for the control of the electro-plating process, we found an AC test signal of frequency 90KHz or higher renders the impedence of the double layer capacitance and the polarization resistance negligible to the solution resistance between the electrodes. Therefore, the measurement of solution impedance becomes possible. When a thin electrode is insulated by a thick epoxy sheath and with the tip face of the electrode brought very close to a flat conducting plate electrode, channel effect would constrain the effective conducting section to the area directly underneath the electrode tip. The effective solution resistance and distance between electrodes exhibit a negative correlation. As the gap distance becomes larger, the conducting cross section becomes wider and the solution resistance becomes smaller. For an electrode of 125uM, the channel effect is apparent in gap shorter than 150uM. Precision surface shape scanning was developed applying this discovery. When the distance between the electrode and the plate electrode becomes bigger than 150uM, or when the height of the deposit grows longer than this value, the solution resistance becomes irrelevant to the distance between the electrodes. The channel for catalytic ions is distributed throughout the space around the electrodes, unlike the conducting wire constraining the conduction evenly in the cross section of the conductor. Therefore, it is ineffective to derive gap distance from the solution resistance.en_US
DC.subject溶液電阻zh_TW
DC.subject電雙層電容zh_TW
DC.subject極化電阻zh_TW
DC.subject頻率響應zh_TW
DC.subject電極間距zh_TW
DC.subject微陽極電鍍zh_TW
DC.subjectmicro anode guided electroplatingen_US
DC.subjectelectrodes distanceen_US
DC.subjectfrequency responseen_US
DC.subjectpolarization resistanceen_US
DC.subjectsolution resistanceen_US
DC.subjectdouble-layer capacitanceen_US
DC.title導電平板之定頻掃描方法研究zh_TW