博碩士論文 965201022 完整後設資料紀錄

DC 欄位 語言
DC.contributor電機工程學系zh_TW
DC.creator林妤穎zh_TW
DC.creatorYu-ying Linen_US
dc.date.accessioned2010-10-22T07:39:07Z
dc.date.available2010-10-22T07:39:07Z
dc.date.issued2010
dc.identifier.urihttp://ir.lib.ncu.edu.tw:88/thesis/view_etd.asp?URN=965201022
dc.contributor.department電機工程學系zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract近年來,憑藉著醫學與超大型積體電路的演進,常見的生理訊號量測儀器已朝向多功能、可攜式與高精準度發展。在量測系統中,除低雜訊生醫放大器外仍需一高精密度之類比數位轉換器將訊號正確地交由數位訊號處理模組進行資料處理與分析。因此,本論文中選擇三角積分調變器 (SDM) 之類比數位轉換器,其可降低前端類比濾波器設計之困難與功率消耗,進而減少整體量測系統面積。 三角積分類比數位轉換器主要由三角積分調變器與數位降頻濾波器所組成。本文所設計之電路結合SC-SDM與SO-SDM之優點並將其整合,以低功率與高解析度為其設計標的完成一應用於所有生理訊號量測之三角積分調變器。電路實現上,在訊號頻寬10KHz、128倍超取樣率與±0.1V的輸入振幅下,所設計之二階三角積分調變器訊號雜訊失真比為70.5dB,有效位元數達到11.7位元且整體晶片消耗之功率為161μW。製作過程使用台積電0.18μm CMOS 1P6M製程,其晶片面積約佔1.035mm2。最後的量測結果顯示訊號雜訊失真比為46.2dB,有效位元數為7.7位元。在1.8V電源供應下,整體晶片消耗之功率約224μW。 zh_TW
dc.description.abstractIn recent years, public bio-signal measurement systems have been developed toward high accuracy, multi-functionality and portability due to the advancement of the medical science and VLSI technology. In addition to the bio-signal analog-front-end (AFE) circuits, measurement systems require a precision analog-to-digital (A/D) converter that can convert signals precisely to digital signal processing for analyzing data. Therefore, we choose the A/D converter which include Sigma-Delta modulator (SDM) to reduce anti-aliasing filter complexity and power consumption, resulting in reducing overall chip area of measurement systems. A Sigma-Delta A/D converter mainly consists of SDM and decimation filter. In this thesis, the proposed SDM combines the advantages of Switched-Capacitor SDM (SC-SDM) and Switched-OPAMP SDM (SO-SDM). The SDM aiming at low power consumption and high resolution is accomplished for all applications of bio-signal measurement. The modulator achieves 70.5dB signal-to-noise and distortion ratio (SNDR), 11.7 effective number of bits (ENOB) , and power consumption 161μW at 10-KHz signal bandwidth with an oversampling ratio (OSR) of 128, and 0.2Vp-p amplitude. The circuit is fabricated in the TSMC 0.18-μm one-poly six-metals CMOS process, and chip area is 1.035mm2. Finally, the measurement results show that signal to noise distortion ratio is 46.2dB, and 7.7 effective number of bits. The measured power consumption is about 224μW for 1.8V power supply. en_US
DC.subject切換式電容zh_TW
DC.subject切換式運算放大器zh_TW
DC.subjectswitched-opampen_US
DC.subjectswitched-capacitoren_US
DC.title兼併切換式電容及切換式放大器且應用於生醫訊號之三角積分調變器zh_TW
dc.language.isozh-TWzh-TW
DC.titleA Sigma-Delta modulator for Bio-signals Measurement System Combining Switched-Capacitor and Switched-OPAMP Techniqueen_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明