摘要(英) |
The World Health Organization published a journal in 2016 pointing out that the global population of diabetes continues to rise and that diabetes is ranked fifth in the country′s mortality rate. This shows that regular blood glucose monitoring is very important, but conventional blood glucose machines cannot measure continuously, and blood collection process causes discomfort to the user. Therefore, in recent years, the development of blood glucose machines has gradually been directed towards non-invasive blood glucose measurement. Among the currently proposed technologies, optical measurement methods are most promising. However, in terms of development, because the glucose signal is rather weak, it is easy to be subject to external factors to interfere with the error during optical measurement. Many of the light sources used in the research are near-infrared light. Therefore, baseline drift that is susceptible to temperature is also found during measurement. Therefore, this study intends to develop a non-invasive blood glucose detection system using dual-lamp measurement technology. The system uses a single-chip microcomputer Arm-Cortex M4 to communicate and connect AFE4490 Chip with the SPI method and to use the PPG measurement probe designed by the laboratory with H-bridge circuit for dual light source PPG data read, PPG signal data sampling rate is set to 500Hz, and then use the Bluetooth method to test the PPG data back to the computer and then use matlab to calculate algorithm.
The system uses near-red light sensitivity to blood glucose as the light source used by the system, and uses green light as the calibration reference to eliminate measurement errors caused by sympathetic nerve changes. The green light and near-infrared light PPG signals of 18 normal healthy people were measured, and the blood glucose level of subjects was changed by taking sugar water, and blood glucose was measured with the commercially available blood glucose meter OneTouch-UltraEasy, and then verified by regression analysis. The error of the blood glucose variation predicted by the system and the actual measurement was 22.57%, confirming the feasibility of the optical blood glucose detection technology. However, in this study, it was found that the values calculated by the algorithm due to differences in the individual′s physiological conditions may have a problem of baseline differences among the subjects. Therefore, the results presented in this system are all the changes in the blood glucose level with Optical activity changes,form this reason our system for the measurement of blood glucose values still need to be recalibrated for individual statment and that can be applied to blood glucose measurement. |
參考文獻 |
[1] Global Report on Diabetes.World Health Organization,2016
[2]S. F. CLARKE and J. R. FOSTER. A history of blood glucose meters and their role.2012
[3]Malanda UL1, Welschen LM, Riphagen II,.Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin.18 January 2012
[4]Advances in Electrochemical Sciences and Engineering : Bioelectrochemistry : Fundamentals, Applications and Recent Developments. Somerset, NJ, US: John Wiley & Sons, 2013.
[5]Ksenia Tonyushkina and James H. Nichols. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
[6]David L. Williams, Alfred R. Doig,and Alexander Korosi. Electrochemical-Enzymatic Analysis of Blood Glucose and Lactate,1970
[7]Biochemistry Department, CentralLaboratory, Royal Infirmary, Sunderland. Determination of Glucose in Blood using Glucose Oxidase with an alternative oxygen acceptor,1969
[8]R. Marbach, Th. Koschinsky, F. A. Gries,H. M. Heise Noninvasive Blood Glucose Assay by Near-Infrared Diffuse Reflectance Spectroscopy of the Human Inner Lip.1993
[9]Chien Chou, Chien-Yuan Han, Wen-Chuan Kuo, Yeu-Chuen Huang, Ching-Mei Feng,and Jenn-Chyang Shyu. Noninvasive glucose monitoring in vivo with an optical heterodyne polarimeter,1998
[10]Katsuhiko Maruo, Mitsuhiro Tsurugi, Jakusei Chin, Tomohiro Ota, Hidenobu Arimoto, Yukio Yamada. Noninvasive Blood Glucose Assay Using a Newly Developed Near-Infrared System,2003
[11]Buford Randall Jean, Eric C. Green, and Melanie J. McClung. A Microwave Frequency Sensor for Non-Invasive Blood-Glucose Measurement,2008
[12]卓貴美.圖解生理學,2版, 五南圖書出版,2008年
[13]Vidhya V , Deepa Unnikrishnan .Synthetic ECG and PPG signal generation using pulse shaping technique. 31 March 2016
[14]成志霞,劉 傑. 基於脈搏波的動脈硬化檢測及其遠程實現.2015
[15]林育德.脈波信號與PPG信號特徵之相關性研究.
[16]李昂澤,林時逸,許惠恒. 升糖素於糖尿病致病機轉角色探討回顧.2013
[17]Pia V Roder1, Bingbing Wu2, Yixian Liu2 and Weiping Han1. Pancreatic regulation of glucose homeostasis.2016
[18]Ramnanan CJ, Edgerton DS, Kraft G, Cherrington AD. Physiologic action of glucagon on liver glucose metabolism. Diabetes Obes Metab 2011; 13 Suppl 1: 118-25
[19]Diabetes Fact sheet N°312. WHO. October 2013 [25 March 2014].
[20]賴邦嶽,張力天,楊文欽 .科學發展501期,56 ~ 62頁.2014
[21]Leutholtz, Brian C.; Ripoll, Ignacio. Diabetes. Exercise and disease management 2nd. Boca Raton: CRC Press. 2011:
[22]Vijan, S. Type 2 diabetes. Annals of Internal Medicine. March 2010, 152 (5): ITC31-15.
[23]衛生福利部國民健康署-糖尿病防治手冊第六章第一節血糖控制與糖尿病併發症 血糖控制與糖尿病併發症
[24]Yasuhiro Yamakoshi,Kenta Matsumura.Side-scattered finger-photoplethysmography: experimental investigations toward practical noninvasive measurement of blood glucose.J. of Biomedical Optics, 22(6), 067001 (2017). doi:10.1117/1.JBO.22.6.067001
[25]Maeda Y.The advantages of wearable green reflected photoplethysmography.J Med Syst. 2011 Oct;35(5):829-34. doi: 10.1007/s10916-010-9506-z. Epub 2010 May 18
[26]Zhong Ren, Guodong Liu, Zhen Huang, Dengji Zhao & Zhihua Xiong.Exploration and Practice in Photoacoustic Measurement for Glucose Concentration Based on Tunable Pulsed Laser Induced Ultrasound.2015
[27]徐雅潔.基於DSP脈搏量測平台的設計及實現.2019 |