參考文獻 |
[1] 彭文陽,「先進馬達與驅動技術專輯」,機械工業雜誌,434期,2019年5月號
[2] P. Pillay, and R. Krishnan, “Application characteristics of permanent magnet synchronous and brushless dc motors for servo drives,” IEEE Trans. Ind. Appl., vol. 27, no. 5, pp. 986-996, Sep./Oct. 1991.
[3] H. Kim, J. Son, and J. Lee, “A high-speed sliding-mode observer for the sensorless speed control of a PMSM,” IEEE Trans. Ind. Electron., vol. 58, no. 9, pp. 4069-4077, Sep. 2011.
[4] S. Kim, Y. D. Yoon, S. K. Sul, and K. Ide, “Maximum torque per ampere (MTPA) control of an IPM machine based on signal injection considering inductance saturation,” IEEE Trans. Power Electron., vol. 28, no. 1, pp. 488-497, Jan. 2013.
[5] F. J. Lin, Y. C. Hung, J. M. Chen, and C. M. Yeh, “Sensorless IPMSM drive system using saliency back-EMF-based intelligent torque observer with MTPA control,” IEEE Trans. Ind. Informat., vol. 10, no. 2, pp. 1226-1241, May 2014.
[6] J. Lemmens, P. Vanassche, and J. Driesen, “PMSM drive current and voltage limiting as a constraint optimal control problem,” IEEE J. Emerg. Sel. Topics Power Electron., vol. 3, no. 2, pp. 326-338, Jun. 2014.
[7] T. Sun, J. Wang, and X. Chen, “Maximum torque per ampere (MTPA) control for interior permanent magnet synchronous machine drives based on virtual signal injection,” IEEE Trans. Power Electron., vol. 30, no. 9, pp. 5036-5045, Sep. 2015.
[8] T. L. Vandoorn, F. M. D. Belie, T. J. Vyncke, J. A. Melkebeek, and P. Lataire, “Generation of multisinusoidal test signals for the identification of synchronous-machine parameters by using a voltage-source inverter,” IEEE Trans. Ind. Electron., vol. 57, no. 1, pp. 430–439, Jan. 2010.
[9] K. M. Rahman and S. Hiti, “Identification of machine parameters of a synchronous motor,” IEEE Trans. Ind. Appl., vol. 41, no. 2, pp. 557–565, Mar./Apr. 2005.
[10] G. D. Feng, C. Y. Lai, and N. C. Kar, ‘‘Novel current injection-based online parameter estimation method for PMSMs considering magnetic saturation,’’ IEEE Trans. Magn., vol. 52, no. 7, Jul. 2016.
[11] G. D. Feng, C. Y. Lai, K. Mukherjee, and N. C. Kar, ‘‘Current injection-based online parameter and VSI nonlinearity estimation for PMSM drives using current and voltage DC components,’’ IEEE Trans. Transpor. Electrifi., vol. 2, no. 2, pp. 119-128, Jun. 2016.
[12] G. L. Wang, C. Li, G. Q. Zhang, and D. G. Xu, ‘‘Self-adaptive stepsize affine projection based parameter estimation of IPMSM using square-wave current injection,’’ CES Trans. Elec. Mach. Sys., vol. 1, no. 1, pp. 48-57r. 2017.
[13] D. Q. Dang, M. S. Rafaq, H. H. Choi, and J. W. Jung, ‘‘Online parameter estimation technique for adaptive control applications of interior PM synchronous motor drives,’’ IEEE Trans. Ind. Electron., vol. 63, no. 3, pp. 1438-1449, Mar. 2016
[14] S. J. Underwood and I. Husain, “Online parameter estimation and adaptive control of permanent-magnet synchronous machines,” IEEE Trans. Ind. Electron., vol. 57, no. 7, pp. 2435–2443, Jul. 2010.
[15] M. X. Bui, M. F. Rahman, D. Guan, and D. Xiao, ‘‘A new and fast method for on-line estimation of d and q axes inductances of interior permanent magnet synchronous machines using measurements of current derivatives and inverter DC-bus voltage,’’ IEEE Trans. Ind. Electron., vol. 66, no. 10, pp. 7488-7497, Oct. 2019
[16] F. J. Lin, S. G. Chen, Y. T. Liu, and W. A. Yu, “Online autotuning of a servo drive using wavelet fuzzy neural network to search for the optimal bandwidth,” IEEE SMC Magazine, Oct., pp. 28-37, 2018.
[17] H. J. Wang, M. Yang, and D. G. Xu, ‘‘Current-loop bandwidth expansion strategy for permanent magnet synchronous motor drives,’’ Proc. 5th IEEE Conf. Ind. Elec. Appl. (ICIEA) Conf., Sep. 2010, pp. 1340-1345
[18] E. J. Fuentes, J. Rodriguez, C. Silva, S. Diaz, and D. E. Quevedo, “Speed control of a permanent magnet synchronous motor using predictive current control,” in Proc. 6th IEEE Int. Power Electron. Motion Control (PEMC) Conf., May. 2009, pp. 390–395.
[19] J. J. Ren, Y. Q. Ye, G. F. Xu, Q. S. Zhao, M. Z. Zhu, “Uncertainty-and- disturbance-estimator-based current control scheme for PMSM drives with a simple parameter tuning algorithm,” IEEE Trans. Power Electron., vol. 32, no. 7, pp. 5712–5722, Jul. 2017.
[20] D. W. Chung and S. K. Sul, “Analysis and compensation of current measurement error in vector-controlled AC motor drives,” IEEE Trans. Ind. Appl., vol. 34, no. 2, pp. 340–345, Mar./Apr. 1998.
[21] K. W. Lee and S. I. Kim, “Dynamic performance improvement of a current offset error compensator in current vector-controlled SPMSM drives,” IEEE Trans. Ind. Electron., vol. 66, no. 9, pp. 6727–6736, Sep. 2019.
[22] F. J. Lin, Y. H. Liao, J. R. Lin, and W. T. Lin, ‘‘Interior permanent magnet synchronous motor drive system with machine learning-based maximum torque per ampere and flux-weakening control,’’ Energies., vol. 14, no. 2, Jan. 2021
[23] S. Y. Chen and F. J. Lin, “Decentralized PID neural network control for five degree-of-freedom active magnetic bearing,” Engineering Applications of AI, vol. 26, pp. 962-973, 2013.
[24] 盛暘科技股份有限公司,數位訊號處理,2007。
[25] Texas Instruments, TMS320F28075 datasheet.
[26] MCP4922 datasheet.
[27] 黃泰寅,「新型每安培最大轉矩控制同步磁阻馬達驅動系統之開發」,中央大學電機工程系,碩士論文,民國106年6月。
[28] 周孝澤,「應用於內藏式永磁同步馬達之智慧型慣量估測及共振頻率偵測」,中央大學電機工程系,碩士論文,民國108年6月。
[29] 林俊儒,「應用於內藏式永磁同步馬達之智慧型高效能控制及小波共振頻率偵測」,中央大學電機工程系,碩士論文,民國109年7月。
[30] 陳家銘,「以單一直流鏈電流感測器結合低轉速轉矩補償之無轉軸位置感測器變頻壓縮機驅動系統開發」,中央大學電機工程系,碩士論文,民國102年6月。
[31] K. Ahsanullah, R. Dutta, and M. F. Rahman, “Analysis of low-speed IPMMs with distributed and fractional slot concentrated windings for wind energy applications,” IEEE Trans. Magn., vol. 53, no. 11, pp. 1-10, Nov. 2017
[32] 陳航生,「內藏式永磁同步馬達之特性分析及其電動機車之應用」,中央大學電機工程系,碩士論文,民國93年5月。
[33] 劉昌煥,「交流電機控制」,東華書局,民國92年。
[34] 高子胤,「以反電動勢為基礎之比例積分微分類神經網路估測器之無感測器變頻壓縮機驅動系統開發」,中央大學電機工程系,碩士論文,民國100年7月。
[35] Z. Chen, M. Tomita, S. Ichikawa, S. Doki, and S. Okuma, “Sensorless control of interior permanent magnet synchronous motor by estimator of an extented electromotive force,” Proc. IECON 2000, pp. 1814-1819, 2000.
[36] H. W. Kim, M. J. Youn, K. Y. Cho, and H. S. Kim, ‘‘Nonlinearity estimation and compensation of PWM VSI for PMSM under resistance and flux linkage uncertainty,’’ IEEE Trans. Control Syst. Tech., vol. 14, no. 4, pp. 589-601, Jul. 2006
[37] K. Liu and Z. Q. Zhu, ‘‘Position offset-based parameter estimation for permanent magnet synchronous machines under variable speed control,’’ IEEE Trans. Power Electron., vol. 30, no. 6, pp. 3438–3446, Jun. 2015.
[38] K. D. Lee, H. W. Lee, J. Lee, and W. H. Kim, ‘‘Analysis of motor performance according to the inductance design of IPMSM,’’ IEEE Trans. Magn., vol. 51, no. 3, Mar. 2015
[39] Keysight 35670A, datasheet.
[40] S. Kim, Y. Yoon, S. Sul and K. Ide, “Maximum torque per ampere (MTPA) control of an IPM machine based on signal injection considering inductance saturation,” IEEE Trans. Power Electron., vol. 28, no. 1, pp. 488-497, Jan. 2013. |