摘要(英) |
The purpose of this study is to improve the curve damper. Due to its asymmetric shape, the strength of the tension side and the compression side is different. If the curve damper is buckled, the strength of the compression side will drop significantly. Therefore, an X-shaped curve damper is used, so that when one side of curve component is under compression, the other side of curve component is under tension. This configuration can prevent the damper from being subjected to a large external force. , the tension side still provides its strength. In addition, in order to improve the phenomenon that the stress of the curved damper is concentrated at the maximum bending moment, the design concept of fully stress is added in this study, so that each section can have a uniform stress distribution, and the material can be used more efficiently.
In order to verify the possibility of the above design, this study carried out a series of component tests for the X-shaped curve damper with different eccentricity, depth and thickness, and observed its mechanical behavior and hysteresis behavior. Load testing with repeated displacements in a moment frame. From the experimental results, it can be known that the phenomenon of obvious decrease of the strength of one side is effectively solved, and the stress is evenly distributed under the design concept of full stress reduction. And in the frame test, it can be seen that the installation of this energy dissipator can effectively increase the energy dissipation capacity of the flexural frame to more than 3 times. From the above results, this design can effectively increase the seismic performance of the flexural frame. |
參考文獻 |
1. Tsai, K.C. and Popov, E.P. (1990), “Seismic Panel Zone on Elastic Story Driftin Steel Moment Resistance Frames”, Journal of Structural Engineering-ASCE, Vol.116, No.12, pp. 3285-3301.
2. Krawinkler, H. (1978), “Shear in Beam-Column Joint in Seismic Design of
Steel Frames”, Engineering Journal, AISC, Vol.15, pp.82-91.
3. Tremblay, R., Timler, P., Bruneau, M. and Filiatrault, A. (1995), “Performance of steel structures during the 1994 Northridge earthquake,” Canadian Journal of Civil Engineering, 22(2), pp. 338-360.
4. Krawinkler, H. (1996), “Earthquake design and performance of steel structures,” Bulletin of the New Zealand National Society for Earthquake Engineering, 29(4), pp. 229-241.
5. Tremblay, R. (2001), “Seismic behavior and design of concentrally braced steel frames”, Engneering Journal, Vol.38, No.3, pp.148-160.
6. Aziznamini, A., and Radziminiski, J.B. (1989), “Static and cyclic performance of semi-rigid steel beam-to-column connections”, Journal of
Structural Engineering, ASCE, Vol.115, No.12, pp.2979-2999
7. Civjan, L., De Matteis, G., and Landolfo, R.(2000), “Retrofit of Pre-Northridge Moment-Resisting Connection”, Journal of Structural Engineering-ASCE, Vol.126, Iss.4, p445-452.
8. Youssef, N.F.G., Bonowitz, D., and Gross, J.L. (1995), “A survey of steel
moment-resisting frame buildings affected by the 1994 Northridge Earthquake,” Report No. NISTIR 5625, National Institute of Standards and Technology, Gaithersburg, MD.
9. 內政部營建署(2006),鋼構造建築物鋼結構設計技術規範。
10. Halim, H. (2015), Performance Improvement of Semi-rigid Moment Frame with Curved Dampers,國立中央大學土木工程學系,碩士論文。
11. 蔡克銓(1993),”三角形鋼板消能器之理論、實驗與應用”,結構工程,第八卷,第四期,頁3-19
12. 陳聖文 (2019), A型隅撐鋼構架耐震性能研究,國立中央大學土木工程學系,碩士論文。
13. ASTM, Standard Test Methods for Tension Testing of Metallic Materials.
14. AISC, Manual of Steel Construction Allowable Stress Design, 9th Edition, American Institute of Steel Construction, Chicago III..
15. 內政部營建署(2011),建築物耐震設計規範及解說,台北。
16. ANSYS. Workbench user’s guide ANSYS Inc.;2016
17. America Institute of Steel Construction.(2005),Seismic Provisions for Structural Steel Building ,AISC 341-05,Chicago,IL.
18. Chopra AK. Dynamics of structures: theory and applications to earthquake engineering, 2nd ed. Englewood Cliffs: prentice Hall; 2001. |