    题名: Applications of Hadamard transform-gas chromatography/mass spectrometry for the detection of hexamethyldisiloxane in a wafer cleanroom
    作者: 王家麟;Cheng, Yuan-Kai;Lin, Cheng-Huang;Kuo, Samuel;Yang, Jonathan;Hsiung, Szu-Yuan;Wang, Jia-Lin
    贡献者: 理學院化學學系
    关键词: absorption;air;Air - analysis;Algorithms;AMC (airborne molecular contaminant);Chromatography;Cleanroom;Cleanrooms;Environment, Controlled;Environmental Monitoring - methods;Fourier Analysis;gas chromatography;Gas Chromatography-Mass Spectrometry - instrumentation;Gas Chromatography-Mass Spectrometry - methods;Gas chromatography/mass spectrometry;Hadamard transform;Hexamethyldisiloxane;HMDS;HMDSO;Inverse;Mass spectrometry;Semiconductors;Signal to noise ratio;Siloxanes - analysis;Wafers
    日期: 2012-01-13
    上传时间: 2026-04-21 13:51:45 (UTC+8)
    出版者: Elsevier;Netherlands: Elsevier B.V
    摘要: 摘要: The Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) technique was successfully employed for the detection of hexamethyldisiloxane (HMDSO, C 6H 18OSi 2) at the sub-nL/L level in a semiconductor wafer cleanroom. Indoor air samples were collected from the room, according to EPA Method TO-17 using a Tedlar bag where the air samples were allowed to pass through an absorption tube for 24 h. The condensed components were then heated and simultaneously injected into a GC column through a Hadamard-injector, which was operated in accordance with the Hadamard codes. Compared to the single injection used in most GC/MS systems, the signal-to-noise (S/N) ratios were substantially improved after the inverse Hadamard transformation of the encoded chromatogram. Under optimized conditions, when cyclic S-matrix orders of 255, 1023 and 2047 were used, the S/N ratios of the HMDSO signals were substantially improved by 7.4-, 15.1- and 20.1-fold, respectively. These improvements are in good agreement with theoretically calculated values (8.0-, 16.0- and 22.6-fold, respectively). We found that when the HT-GC/MS technique was applied, HMDSO could be detected at the 0.1 nL/L level.
    其他題名: J Chromatogr A
    出版者: Netherlands: Elsevier B.V
    出版日期: 2012-01-13
    出處: Journal of Chromatography A, 2012-01, Vol.1220 (13), p.143-146
    版權: 2011 Elsevier B.V.
    版權: Copyright © 2011 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0021-9673
    識別號: ISSN: 1873-3778
    識別號: EISSN: 1873-3778
    識別號: DOI: 10.1016/j.chroma.2011.12.006
    識別號: PMID: 22192564
    显示于类别:[化學學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML15检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明