中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/101808
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82858789      在线人数 : 1624
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    NCU Institutional Repository > 理學院 > 化學學系 > 期刊論文 >  Item 987654321/101808


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/101808


    题名: Construction of a cryogen-free thermal desorption gas chromatographic system with off-the-shelf components for monitoring ambient volatile organic compounds
    作者: 歐陽長風;Ou-Yang, Chang-Feng;Liao, Wei-Cheng;Wang, Pei-Chieh;Fan, Gang-Jei;Hsiao, Chien-Cheng;Chuang, Ming-Tung;Chang, Chih-Chung;Lin, Neng-Huei;Wang, Jia-Lin
    贡献者: 理學院化學學系
    关键词: air;Air quality/ Deans switch;Analyzers;carbon monoxide;Chromatography;Desorption;detection limit;diurnal variation;ethane;Ethylene;Gas chromatography;Hydrocarbons;isoprene;Linearity;monitoring;Organic compounds;Ozone precursors;quality control;VOCs;Volatile compounds;Volatile organic compounds
    日期: 2016-04-01
    上传时间: 2026-04-21 14:45:37 (UTC+8)
    出版者: Wiley-VCH Verlag;Germany: Blackwell Publishing Ltd
    摘要: 摘要: An automated gas chromatographic system aimed at performing unattended measurements of ambient volatile organic compounds was configured and tested. By exploiting various off‐the‐shelf components, the thermal desorption unit was easily assembled and can be connected with any existing commercial gas chromatograph in the laboratory to minimize cost. The performance of the complete thermal desorption gas chromatographic system was assessed by analyzing a standard mixture containing 56 target nonmethane hydrocarbons from C2–C12 at sub‐ppb levels. Particular attention was given to the enrichment efficiency of the C2 compounds, such as ethane (b.p. = –88.6°C) and ethylene (b.p. = –104.2°C), due to their extremely high volatilities. Quality assurance was performed in terms of the linearity, precision and limits of detection of the target compounds. To further validate the system, field measurements of target compounds in ambient air were compared with those of a commercial total hydrocarbon analyzer and a carbon monoxide analyzer. Highly coherent results from the three instruments were observed during a two‐month period of synchronized measurements. Moreover, the phenomenon of opposite diurnal variations between the biogenic isoprene and anthropogenic species was exploited to help support the field applicability of the thermal desorption gas chromatographic method.
    其他題名: J. Sep. Science
    出版者: Germany: Blackwell Publishing Ltd
    出版日期: 2016-04
    出處: Journal of separation science, 2016-04, Vol.39 (8), p.1489-1499
    資源來源: Wiley Journals
    版權: 2016 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim
    版權: 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
    版權: 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
    識別號: ISSN: 1615-9306
    識別號: EISSN: 1615-9314
    識別號: DOI: 10.1002/jssc.201501336
    識別號: PMID: 26924196
    显示于类别:[化學學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML19检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明