中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/101868
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82915344      在线人数 : 2313
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/101868


    题名: A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
    作者: 陳文逸;Sung, Tzu-Cheng;Chen, Wen-Yih;Shah, Pramod;Chen, Chien-Sheng
    贡献者: 工學院化學工程與材料工程學系
    关键词: 1,2-Dipalmitoylphosphatidylcholine - chemistry;631/92;639/638/11/872;9/10;Aptamers;Aptamers, Nucleotide - chemical synthesis;Aptamers, Nucleotide - chemistry;Binding sites;Binding, Competitive;Biosensing Techniques;Biotin;Biotin - analysis;Cholesterol;Cholesterol - chemistry;Competition;Humanities and Social Sciences;Limit of Detection;Lipids;Liposomes;Liposomes - chemistry;Multidisciplinary;Phosphatidylglycerols - chemistry;Polyethylene Glycols - chemistry;Science;Streptavidin;Streptavidin - chemistry
    日期: 2016-02-23
    上传时间: 2026-04-21 14:48:49 (UTC+8)
    出版者: Nature Publishing Group;London: Springer Science and Business Media LLC
    摘要: 摘要: AbstractBiotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays.
    其他題名: Sci Rep
    出版者: London: Springer Science and Business Media LLC
    出版日期: 2016-02-23
    出處: Scientific Reports, 2016-02, Vol.6 (1), p.21369-21369, Article 21369
    資源來源: Springer Nature Link Open Access Journals
    版權: The Author(s) 2016
    版權: Copyright Nature Publishing Group Feb 2016
    版權: Copyright © 2016, Macmillan Publishers Limited 2016 Macmillan Publishers Limited
    識別號: ISSN: 2045-2322
    識別號: EISSN: 2045-2322
    識別號: DOI: 10.1038/srep21369
    識別號: PMID: 26903199
    显示于类别:[化學工程與材料工程學系 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML21检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明