    題名: A new way to analyze resuscitation quality by reviewing automatic external defibrillator data
    作者: 羅孟宗;Lin, Lian-Yu;Lo, Men-Tzung;Chiang, Wen-Chu;Lin, Chen;Ko, Patrick Chow-In;Hsiung, Kuang-Hua;Lin, Jiunn-Lee;Chen, Wen-Jone;Ma, Matthew Huei-Ming
    貢獻者: 生醫理工學院生醫科學與工程學系
    關鍵詞: Adult;Aged;Aged, 80 and over;Algorithms;Auto-correlation function;Automated external defibrillator;Automation;Cardiopulmonary resuscitation;Cardiopulmonary Resuscitation - instrumentation;Cardiopulmonary Resuscitation - standards;Defibrillators - standards;Electrocardiography - methods;Emergency;Emergency Medical Services - methods;Empirical mode decomposition;Female;Heart Arrest - etiology;Heart Arrest - therapy;Humans;Male;Middle Aged;Out-of-hospital cardiac arrest;Quality Assurance, Health Care;Ventricular Fibrillation - complications;Ventricular Fibrillation - diagnosis
    日期: 2012-02-01
    上傳時間: 2026-04-23 11:14:51 (UTC+8)
    出版者: Elsevier Ireland Ltd;Ireland: Elsevier Ireland Ltd
    摘要: 摘要: High quality cardiopulmonary resuscitation (CPR) plays an important role in survival of out-of-hospital cardiac arrests (OHCAs). We have developed an algorithm to automatically identify the quality of chest compressions from data retrieved from automatic external defibrillators (AEDs). Electrocardiographic (ECG) signals retrieved from AEDs were analyzed by a newly developed algorithm to identify fluctuations in CPR. The algorithm contained three steps. First, it decomposed the AED signals into several intrinsic mode fluctuations (IMFs) by empirical mode decomposition (EMD). Second, it identified the dominant IMFs that carried the chest compression signals and weighted the IMFs to both enhance the chest compression oscillations and filter the noise. Third, it calculated the autocorrelation function (ACF) of the reconstructed signals and tested their periodicity. Using this algorithm, several CPR quality indicators were automatically calculated minute-by-minute and compared with those derived by audio and visual review of AED data by experienced physicians. A total of 77 (29 women, 48 men) OHCA patients were enrolled, and 351 one-min segments were analyzed. The results showed that the CPR quality parameters calculated from the algorithm were highly correlated with those from the manual review (all P<0.001). The limits of agreement by Bland–Altman analysis were acceptable for chest compression number, total flow time, and no flow time, but not for CPR rate. We also demonstrated that only 41.8±29.8% of time was spent in chest compressions and only 7.5±16.8% was spent in adequate chest compressions. Our results demonstrated that several indicators of CPR quality can be precisely and automatically determined by analyzing the ECG signals from AEDs using EMD and autocorrelograms.
    其他題名: Resuscitation
    出版者: Ireland: Elsevier Ireland Ltd
    出版日期: 2012-02-01
    出處: Resuscitation, 2012-02, Vol.83 (2), p.171-176
    版權: 2011 Elsevier Ireland Ltd
    版權: Elsevier Ireland Ltd
    版權: Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
    識別號: ISSN: 0300-9572
    識別號: ISSN: 1873-1570
    識別號: EISSN: 1873-1570
    識別號: DOI: 10.1016/j.resuscitation.2011.10.025
    識別號: PMID: 22063728
    顯示於類別:[生醫科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML29檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明