中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/102934
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 94201/94201 (100%)
Visitors : 81550649      Online Users : 3739
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: https://ir.lib.ncu.edu.tw/handle/987654321/102934


    Title: Rolling ball sifting algorithm for the augmented visual inspection of carotid bruit auscultation
    Authors: 黃輝揚;Huang, Adam;Lee, Chung-Wei;Liu, Hon-Man
    Contributors: 生醫理工學院生醫科學與工程學系
    Keywords: 639/166/985;692/4019;692/53/2421;Humanities and Social Sciences;multidisciplinary;Science
    Date: 2016-07-25
    Issue Date: 2026-04-23 11:20:25 (UTC+8)
    Publisher: Nature Publishing Group;London: Nature Publishing Group UK
    Abstract: 摘要: Carotid bruits are systolic sounds associated with turbulent blood flow through atherosclerotic stenosis in the neck. They are audible intermittent high-frequency (above 200 Hz) sounds mixed with background noise and transmitted low-frequency (below 100 Hz) heart sounds that wax and wane periodically. It is a nontrivial task to extract both bruits and heart sounds with high fidelity for further computer-aided auscultation and diagnosis. In this paper we propose a rolling ball sifting algorithm that is capable to filter signals with a sharper frequency selectivity mechanism in the time domain. By rolling two balls (one above and one below the signal) of a suitable radius, the balls are large enough to roll over bruits and yet small enough to ride on heart sound waveforms. The high-frequency bruits can then be extracted according to a tangibility criterion by using the local extrema touched by the balls. Similarly, the low-frequency heart sounds can be acquired by a larger radius. By visualizing the periodicity information of both the extracted heart sounds and bruits, the proposed visual inspection method can potentially improve carotid bruit diagnosis accuracy.
    其他題名: Sci Rep
    出版者: London: Nature Publishing Group UK
    出版日期: 2016-07-25
    出處: Scientific reports, 2016-07, Vol.6 (1), p.30179, Article 30179
    資源來源: Springer Nature Link Open Access Journals
    版權: The Author(s) 2016
    版權: Copyright © 2016, Macmillan Publishers Limited 2016 Macmillan Publishers Limited
    識別號: ISSN: 2045-2322
    識別號: EISSN: 2045-2322
    識別號: DOI: 10.1038/srep30179
    識別號: PMID: 27452722
    Appears in Collections:[Department of Biomedical Sciences and Engineering ] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML21View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明