    題名: A study of new pulse auscultation system
    作者: 張榮森;Chen, Ying-Yun;Chang, Rong-Seng
    貢獻者: 理學院光電科學與工程學系
    關鍵詞: Accuracy;Algorithms;Auscultation;Auscultation - methods;Circuit design;Filtering;Filtration;Fourier Analysis;Fourier transforms;Heart Rate;Humans;Medicine, Chinese Traditional;Microphones;Pulse;pulse, auscultation, condenser microphone;Sensors;Sound;Traditional Chinese medicine;Waveforms
    日期: 2015-04-14
    上傳時間: 2026-04-23 11:22:06 (UTC+8)
    出版者: MDPI Multidisciplinary Digital Publishing Institute;Switzerland: MDPI AG
    摘要: 摘要: This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT) and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine’s pulsing techniques, where pulse signals at places called “cun”, “guan” and “chi” of the left hand were measured during lifting (100 g), searching (125 g) and pressing (150 g) actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners’ objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.
    其他題名: Sensors (Basel)
    出版者: Switzerland: MDPI AG
    出版日期: 2015-04-14
    出處: Sensors (Basel, Switzerland), 2015-04, Vol.15 (4), p.8712-8731
    資源來源: Publicly Available Content Database
    版權: Copyright MDPI AG 2015
    版權: 2015 by the authors; licensee MDPI, Basel, Switzerland. 2015
    識別號: ISSN: 1424-8220
    識別號: EISSN: 1424-8220
    識別號: DOI: 10.3390/s150408712
    識別號: PMID: 25875192
    顯示於類別:[光電科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML14檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明