English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81540599      線上人數 : 2904
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/103085


    題名: The use of signal analyses of ventricular tachycardia electrograms to predict the response of antitachycardia pacing in patients with implantable cardioverter-defibrillators
    作者: 林澂;TUAN, TA-CHUAN;LO, MEN-TZUNG;LIN, YENN-JIANG;HSIEH, WAN-HSIN;LIN, CHEN;HUANG, NORDEN E.;LO, LI-WEI;CHAO, TZE-FAN;LIAO, JO-NAN;HSIEH, YU-CHENG;WU, TSU-JUEY;CHEN, SHIH-ANN
    貢獻者: 生醫理工學院生醫科學與工程學系
    關鍵詞: Aged;Aged, 80 and over;antitachycardia pacing;Cardiac Pacing, Artificial - methods;Cohort Studies;Defibrillators, Implantable;Electrocardiography - instrumentation;Electrocardiography - methods;electrogram;Female;Humans;implantable cardioverter-defibrillator;Male;Middle Aged;Predictive Value of Tests;signal analysis;Signal Processing, Computer-Assisted - instrumentation;Tachycardia, Ventricular - physiopathology;Tachycardia, Ventricular - therapy;ventricular tachycardia
    日期: 2014-01-01
    上傳時間: 2026-04-23 11:23:02 (UTC+8)
    出版者: Wiley-Blackwell Publishing Ltd;United States: Blackwell Publishing Ltd
    摘要: 摘要: ICDs and Signal Analyses Introduction Antitachycardia pacing (ATP), a quick, painless, and effective therapy available in implantable cardioverter‐defibrillators (ICDs), can terminate most, but not all, sustained ventricular tachycardias (VTs). This study investigated the possible ventricular electrogram (EGM) factors for predicting the effectiveness of ATP therapy from ICD recordings. Methods and Results In this study, we analyzed 113 EGMs of VT episodes acquired from 20 patients who received ATP or shock to terminate tachyarrhythmias during follow‐up after ICD implantations. The relationship between the outcome of ATP and VT EGM features (such as voltage, width, cycle length, and beat‐to‐beat morphologic variation) was investigated. The divergence (beat‐to‐beat morphologic variation) of the VT EGMs was determined by calculating the total deviation of all EGMs away from the average template after all VT EMGs were aligned. In total, 72 (63.7%) successful (Group I) and 41 (36.3%) unsuccessful (Group II) ATP therapy episodes were analyzed. The mean amplitude, cycle length, and EGM width were similar between these 2 groups (P > 0.05). A multivariate analysis demonstrated that the only predictor of successful ATP was the divergence among the VT EGMs (0.56 ± 0.32 vs 1.07 ± 0.64, P < 0.001, for Groups 1 and 2, respectively). The optimal cutoff value for determining a successful ATP therapy was 0.73 (with an area under the curve of 0.769, sensitivity of 81.9% [95% CI = 71.1–90.0], and specificity of 65.9% [95% CI = 49.4–79.9], P < 0.0001). Conclusion Signal analyses from stored EGMs of VT can predict the response of ATP therapy in patients with ICD implantations. A lesser ventricular beat‐to‐beat morphologic variation in the intracardiac recordings from ICDs correlated with a higher probability of a successful ATP.
    其他題名: J Cardiovasc Electrophysiol
    出版者: United States: Blackwell Publishing Ltd
    出版日期: 2014-04
    出處: Journal of cardiovascular electrophysiology, 2014-04, Vol.25 (4), p.411-417
    資源來源: Wiley Online Library - AutoHoldings Journals
    版權: 2013 Wiley Periodicals, Inc.
    版權: Copyright © 2014 Wiley Periodicals, Inc.
    識別號: ISSN: 1045-3873
    識別號: ISSN: 1540-8167
    識別號: EISSN: 1540-8167
    識別號: DOI: 10.1111/jce.12340
    識別號: PMID: 24320556
    顯示於類別:[生醫科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML23檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明