English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81539697      線上人數 : 3168
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/103213


    題名: Design optimization of multi-pinhole micro-SPECT configurations by signal detection tasks and system performance evaluations for mouse cardiac imaging
    作者: 陳怡君;Lee, M-W;Lin, W-T;Chen, Y-C
    貢獻者: 理學院光電科學與工程學系
    關鍵詞: Animals;Cardiac Imaging Techniques - instrumentation;Cardiac Imaging Techniques - methods;Gamma Cameras;image quality;Mice;multi-pinhole;Sensitivity and Specificity;SPECT;system performance;Tomography, Emission-Computed, Single-Photon - methods
    日期: 2015-01-10
    上傳時間: 2026-04-23 11:25:49 (UTC+8)
    出版者: IOP Publishing Ltd.;England: IOP Publishing
    摘要: 摘要: An optimized configuration of multi-pinhole aperture can improve the spatial resolution and the sensitivity of pinhole SPECT simultaneously. In this study, an optimization strategy of the multi-pinhole configuration with a small detector is proposed for mouse cardiac imaging. A 14 mm-diameter spherical field-of-view (FOV) is used to accommodate the mouse heart. To accelerate the optimization process, the analytic models are applied to rapidly obtain the projection areas of the FOV, the sensitivities and the spatial resolutions of numerous system designs. The candidates of optimal multi-pinhole configuration are then decided by the preliminary evaluations with the analytic models. Subsequently, the pinhole SPECT systems equipped with the designed multi-pinhole apertures are modeled in GATE to generate the imaging system matrices (H matrices) for the system performance assessments. The area under the ROC curves (AUC) of the designed systems is evaluated by signal-known-exactly/background-known-statistically detection tasks with their corresponding H matrices. In addition, the spatial resolutions are estimated by the Fourier crosstalk approach, and the sensitivities are calculated with the H matrices of designed systems, respectively. Furthermore, a series of OSEM reconstruction images of synthetic phantoms, including the hot-rod phantom, mouse heart phantom and Defrise phantom, are reconstructed with the H matrices of designed systems. To quantify the sensitivity and resolution competition in the optimization process, the AUC from the detection tasks and the resolution estimated by the Fourier crosstalk are used as the figure of merits. A trade-off function of AUC and resolution is introduced to find the optimal multi-pinhole configuration. According to the examining results, a 22.5° rotated detector plus a 4-pinhole aperture with 22.5° rotation, 20% multiplexing and 1.52X magnification is the optimized multi-pinhole configuration for the micro pinhole-SPECT applied to mouse cardiac imaging with a camera of 49 × 49 mm2 active area.
    其他題名: PMB
    其他題名: Phys. Med. Biol
    出版者: England: IOP Publishing
    出版日期: 2015-01-21
    出處: Physics in medicine & biology, 2015-01, Vol.60 (2), p.473-499
    資源來源: Institute of Physics Journals
    版權: 2015 Institute of Physics and Engineering in Medicine
    識別號: ISSN: 0031-9155
    識別號: ISSN: 1361-6560
    識別號: EISSN: 1361-6560
    識別號: DOI: 10.1088/0031-9155/60/2/473
    識別號: PMID: 25548860
    識別號: CODEN: PHMBA7
    顯示於類別:[光電科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML14檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明