 |
English
|
正體中文
|
简体中文
|
Items with full text/Total items : 94201/94201 (100%)
Visitors : 81547654
Online Users : 1634
|
|
|
Loading...
|
Please use this identifier to cite or link to this item:
https://ir.lib.ncu.edu.tw/handle/987654321/103315
|
| Title: | A single use biosensor for the detection of nitric oxide (NO) at ppb and sub-μM level in gas-and liquid- phase media |
| Authors: | 劉炯權;K. Butler, Samantha;Li, Freda;Chaube, Ruchi;Laskowski, Dan;C. Liu, Chung |
| Contributors: | 工學院材料科學與工程研究所 |
| Date: | 2016-01-01 |
| Issue Date: | 2026-04-23 11:27:55 (UTC+8) |
| Publisher: | Bentham Science Publishers B.V.;Bentham Science Publishers Ltd |
| Abstract: | 摘要: Nitric Oxide (NO) is an important, rapid assay biomarker of many known diseases, including asthma, chronic obstructive pulmonary disease (COPD) as well as other respiratory infections, septic shock, Parkinson's diseases and Alzheimer's dementia. Therefore, the detection and measurement of NO in a physiological fluid, either in gas or in liquid phase, are scientifically and clinically significant. The objective of this research is to develop a single-use, disposable cost effective in vitro NO biosensor which can measure NO of ppb (parts per billion) level in gas phase and sub-µM (sub micro mole) level in liquid phase. This biosensor is a thin film platinum based electrochemical sensor. Ni (II) tetrakis (3-methoxy-4-hydroxyphenlyl) porphyrin is mixed with diethylene glycol and Nafion forming a NO selective membrane-electrolyte. Reactive sputtering, laser ablation, thick film printing technologies are used to fabricate the biosensor on a roll-to-roll cost effective processing. Differential pulse voltammetry (DPV) is employed as the measurement technique. The results of this NO biosensor show that this biosensor can measure NO down to 5ppb in gas phase and 0.00242µM of NO in PBS solution (liquid phase). Fabrication and test procedures of this NO biosensor are described in this presentation. In conclusion, this development is scientifically successful and is described as sensor for nitric oxide detection WO2015143197 (2015) by World Intellectual Property Organization on September 24, 2015. 其他題名: CBM 出版者: Bentham Science Publishers Ltd 出版日期: 2016 出處: Current biomarkers, 2016, Vol.6 (1), p.3-9 識別號: ISSN: 2468-4228 識別號: DOI: 10.2174/2210309006666160502112925 |
| Appears in Collections: | [Institute of Materials Science and Engineering] journal & Dissertation
|
Files in This Item:
| File |
Description |
Size | Format | |
| index.html | | 0Kb | HTML | 17 | View/Open |
|
All items in NCUIR are protected by copyright, with all rights reserved.
|
::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::