中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/103484
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94201/94201 (100%)
造访人次 : 81726816      在线人数 : 1345
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/103484


    题名: Effect of coating thickness on the cutting sharpness and durability of Zr-based metallic glass thin film coated surgical blades
    作者: 蔡佩樺;Tsai, P.H.;Li, T.H.;Hsu, K.T.;Chiou, J.W.;Jang, J.S.C.;Chu, J.P.
    贡献者: 工學院材料科學與工程研究所
    关键词: Biomedical applications;Blades (cutting);Coating;Cutting;Cutting test;Durability;Metallic glass;Metallic glasses;Sharpness;Thin film;Thin films;Zirconium base alloys
    日期: 2016-11-01
    上传时间: 2026-04-23 11:31:24 (UTC+8)
    出版者: Elsevier;Elsevier B.V
    摘要: 摘要: The cutting sharpness and durability of commercial blades without and with 200–500nm thicknesses of Zr-Cu-Al-Ag-Si and Zr-Cu-Ni-Al-Si metallic glass thin film (MGTF) coating were systematically characterized and evaluated. The amorphous states of all MGTF coatings were examined by grazing incident X-ray diffraction analysis. The observation of scanning electron microscopy reveals that MGTF coated blades own much smoother surface than the commercial one which indicates smaller friction force during cutting process. Results of sharpness test in the beginning reveal that all MGTF-coated blades possess smaller value of blade sharpness index (BSI) than the commercial one. The cutting durability of the MGTF-coated and commercial blades was evaluated by the variation of BSI values by 25cm cutting test. The commercial blade was blunted (BSI=0.49) after 20cm cutting path. Conversely, the 300nm-thick MGTF-coated blades present the smallest BSI value after 20cm cutting path in comparison with other thicknesses MGTF-coated blades and commercial blade. As a result, the cutting durability of surgical blade can be significant improved by Zr-based MGTF-coating, can keep the BSI value less than 0.45 after 20cm cutting test. •Zr based metallic glass thin film coated on commercial surgical blades.•Metallic glass thin film coated blades exhibit much smoother surface.•Metallic glass thin film coated blades show the better initial cutting sharpness.•Metallic glass thin film coated blades show the better cutting durability.
    出版者: Elsevier B.V
    出版日期: 2016-11-01
    出處: Thin solid films, 2016-11, Vol.618, p.36-41
    版權: 2016 Elsevier B.V.
    識別號: ISSN: 0040-6090
    識別號: EISSN: 1879-2731
    識別號: DOI: 10.1016/j.tsf.2016.05.020
    显示于类别:[材料科學與工程研究所 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML30检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明