    Title: Electrochemical and biocompatibility response of newly developed TiZr-based metallic glasses
    Authors: 鄭憲清;Huang, C.H.;Huang, Y.S.;Lin, Y.S.;Lin, C.H.;Huang, J.C.;Chen, C.H.;Li, J.B.;Chen, Y.H.;Jang, J.S.C.
    Contributors: 工學院材料科學與工程研究所
    Keywords: Amorphous materials;Animals;Biocompatibility;Biocompatible Materials;Biomedical materials;Copper;Cytotoxicity;Electrochemical response;Electrochemistry;Epiphyseal growth plate;Glass;In vitro testing;In vivo tests;Male;Mass Spectrometry;Metallic glasses;Rabbits;Titanium - chemistry;Viability;Zirconium - chemistry
    Date: 2014-10-01
    Issue Date: 2026-04-23 11:33:20 (UTC+8)
    Publisher: Elsevier BV;Netherlands: Elsevier B.V
    Abstract: 摘要: This paper presents systematical investigations, including electrochemical activity, MTT cell assay and in vivo test, on the biocompatibility of three metallic glasses. The electrochemical behaviors and the cell toxicity of two newly developed TiZr-based metallic glasses (MGs), Ti42Zr40Si15Ta3 and Ti40Zr40Si15Cu5, with lower or without unfavorable elements are systematically investigated. Results show that the MGs with low Cu content exhibit a low electrochemical response. Cytotoxicity tests for the MGs and the mediums after the potential state test are evaluated with in vitro MTT assays. The solid specimens and the mediums after the potential state test for the pure Ti, Ti42Zr40Si15Ta3 and Ti40Zr40Si15Cu5 exhibit no significant cytotoxicity in the MTT test, while the tested medium for Ti45Cu35Zr20 MG shows lower cell viability. The inductively coupled plasma-mass spectrometry (ICP-MS) results also indicate that the Cu-rich sample released a significant amount of ions which may be the major factor causing the low viability in the MTT test. The good healing condition and the low C-reactive protein (CRP) index for the implanted New Zealand rabbits in a one-month in vivo test also show the satisfactory short-term biocompatibility of the TiZr-based MGs. The electrochemical measurements, in vitro, and in vivo experiments confirm that the developed TiZr-based MGs with lower Cu content (≦5%) are promising for biomedical purposes.
    其他題名: Mater Sci Eng C Mater Biol Appl
    出版者: Netherlands: Elsevier B.V
    出版日期: 2014-10-01
    出處: Materials Science & Engineering C, 2014-10, Vol.43, p.343-349
    資源來源: Elsevier ScienceDirect Journals Complete
    版權: 2014 Elsevier B.V.
    版權: Copyright © 2014 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0928-4931
    識別號: ISSN: 1873-0191
    識別號: EISSN: 1873-0191
    識別號: DOI: 10.1016/j.msec.2014.06.040
    識別號: PMID: 25175222
    Appears in Collections:[Institute of Materials Science and Engineering] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML14View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明