English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81564035      線上人數 : 4001
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/104429


    題名: Use of liposomal amplifiers in total internal reflection fluorescence fiber-optic biosensors for protein detection
    作者: 陳啟昌;Chang, Ying-Feng;Fu, Chen;Chen, Yi-Ting;Fang-Ju Jou, Amily;Chen, Chii-Chang;Chou, Chien;Annie Ho, Ja-an
    貢獻者: 理學院光電科學與工程學系
    關鍵詞: Amplifiers;Biosensing Techniques - instrumentation;Biosensors;cost effectiveness;detection limit;Equipment Design;Equipment Failure Analysis;Evanescent wave-excited fluorescence;Excitation;Fiber Optic Technology - instrumentation;fiber optics;Fiber-optic biosensors;Fluorescence;Format;Immunoassay - instrumentation;immunoassays;immunoglobulin G;Immunoglobulin G - analysis;Liposomes;Liposomes - chemistry;polyclonal antibodies;Protein Array Analysis - instrumentation;Protein detection;Proteins;Reflection;Spectrometry, Fluorescence - instrumentation;Target detection
    日期: 2016-03-15
    上傳時間: 2026-04-23 11:50:05 (UTC+8)
    出版者: Elsevier Ltd.;England: Elsevier B.V
    摘要: 摘要: Evanescent-wave excited fluorescence technology has been demonstrated to enhance sensitivity and reduce matrix effects, making it suitable for biosensor development. In this study, we developed a liposome-based, total internal reflection fluorescence, fiber-optic biosensor (TIRF-FOB) for protein detection, which integrates a liposomal amplifier and sandwich immunoassay format with TIRF-FOB. In addition, the antibody-tagged and fluorophore-entrapped liposomes for heterogeneous detection of target molecules were designed and synthesized. This biosensor successfully detected the target protein (model analyzed here is IgG) with a limit of detection (LOD) of 2.0 attomoles for the target protein (equivalent to 2.0pg/mL of protein presented in 150μL of sample solution). The features of this ultra-sensitive liposomal TIRF-FOB are (i) fluorescence is excited via evanescent waves and amplified via liposomes; (ii) the use of two polyclonal antibodies in the sandwich assay format increases the specificity and lowers the cost of our assay. Based on the exceptional detection sensitivity and cost-effectiveness, we believe that the proposed biosensor has great potential as a practical, clinical diagnostic tool in the near future. •Evanescent-wave excited fluorescence technology was used to develop a new sensor.•Liposomal amplifiers and sandwich immunoassay format were integrated with TIRF-FOB.•Ultra-sensitivity of TIRF-FOB was achieved by liposomal signal amplification.•The proposed biosensor has great potential as a practical, clinical diagnostic tool.
    其他題名: Biosens Bioelectron
    出版者: England: Elsevier B.V
    出版日期: 2016-03-15
    出處: Biosensors & bioelectronics, 2016-03, Vol.77, p.1201-1207
    版權: 2015 Elsevier B.V.
    版權: Copyright © 2015 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0956-5663
    識別號: EISSN: 1873-4235
    識別號: DOI: 10.1016/j.bios.2015.10.012
    識別號: PMID: 26595485
    顯示於類別:[光電科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML15檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明