 |
English
|
正體中文
|
简体中文
|
全文筆數/總筆數 : 94274/94274 (100%)
造訪人次 : 82906556
線上人數 : 2402
|
|
|
資料載入中.....
|
請使用永久網址來引用或連結此文件:
https://ir.lib.ncu.edu.tw/handle/987654321/104768
|
| 題名: | Development and diagnosis of a 1-kW self-sustainable proton exchange membrane fuel cell system with a methanol reformer |
| 作者: | 陳震宇;Chen, Chen-Yu;Hsu, Sui-Wei;Yan, Wei-Mon;Lai, Wei-Hsiang;Huang, Keng-Pin;Yang, Chen-Cheng;Chen, Chun-Chi;Lai, Ming-Ping |
| 貢獻者: | 工學院能源工程研究所 |
| 關鍵詞: | Applied sciences;Direct energy conversion and energy accumulation;Electric potential;Electric power generation;Electrical engineering. Electrical power engineering;Electrical power engineering;Electrochemical conversion: primary and secondary batteries, fuel cells;Energy;Energy. Thermal use of fuels;Equipments for energy generation and conversion: thermal, electrical, mechanical energy, etc;Exact sciences and technology;Fuel cells;Generators;High voltage or high current generators;Membranes;Methyl alcohol;Power electronics, power supplies;Stacks;Various equipment and components;Voltage |
| 日期: | 2013-07-22 |
| 上傳時間: | 2026-04-23 11:57:40 (UTC+8) |
| 出版者: | The American Society of Mechanical Engineers(ASME);New York, NY: ASME |
| 摘要: | 摘要: A reformed methanol fuel cell system is one of the most practical of all types of fuel cell systems. It is regarded as one of the best candidates for stationary applications, such as residential power generators, uninterruptible power supply systems, power generators for cell base stations, or power generators in outlying areas. In this research, a 1-kW self-sustainable proton exchange membrane fuel cell system with a methanol reformer is designed and tested. The system performance test and in situ stack monitoring show that the system is stable and reliable. During normal operation, the maximum voltage deviation among the individual cells, which is caused by a nonuniform temperature distribution in the proton exchange membrane fuel cell stack, is 25 mV. The peak power output of the system reaches 1.4 kW. The maximum electrical efficiency is 65.2% at a system power of 1 kW. The system is operated at 1 kW for 4 h, during which the decay rate of the stack power is 0.94%. During the stability test, voltage fluctuation occurs in a certain cell because of a flooding phenomenon. A demonstration is also presented in this paper to show the system’s practicability and commercial potential. 其他題名: J. Electrochem. En. Conv. Stor 出版者: New York, NY: ASME 出版日期: 2013-06-01 出處: Journal of electrochemical energy conversion and storage, 2013-06, Vol.10 (3), p.1-9 資源來源: Alma/SFX Local Collection 版權: 2014 INIST-CNRS 識別號: ISSN: 2381-6872 識別號: ISSN: 1550-624X 識別號: EISSN: 1551-6989 識別號: DOI: 10.1115/1.4024256 |
| 顯示於類別: | [能源工程研究所 ] 期刊論文
|
文件中的檔案:
| 檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
| index.html | | 0Kb | HTML | 26 | 檢視/開啟 |
|
在NCUIR中所有的資料項目都受到原著作權保護.
|
::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::