English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81621382      線上人數 : 6776
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/106527


    題名: Adaptive SSVEP-based BCI system with frequency and pulse duty-cycle stimuli tuning design
    作者: 徐國鎧;Shyu, Kuo-Kai;Chiu, Yun-Jen;Lee, Po-Lei;Liang, Jia-Ming;Peng, Shao-Hwo
    貢獻者: 資訊電機學院電機工程學系
    關鍵詞: Analog-Digital Conversion;Brain-computer interface (BCI);Brain-Computer Interfaces;Control systems;Electric potential;Electric Stimulation;Electrodes;Electroencephalography;Encoding;Equipment Design;Evoked Potentials, Somatosensory - physiology;Humans;Photic Stimulation;Signal-To-Noise Ratio;Somatosensory Cortex - physiology;Steady-state;steady-state visual evoked potential (SSVEP);Time-frequency analysis;Visualization
    日期: 2013-09-17
    上傳時間: 2026-04-23 13:26:24 (UTC+8)
    出版者: Institute of Electrical and Electronics Engineers Inc.;United States: IEEE
    摘要: 摘要: This study aims to design a steady state visual evoked potentials (SSVEP) based brain-computer interface (BCI) system with only three electrodes. It is known that low frequency flickering induces more intensive SSVEP, but might cause users feel uncomfortable and easily tired. Therefore, this paper proposes a novel middle/high frequency flickering stimulus. However, users show different SSVEP responses when gazing at the same stimuli. It is improper to design fixed frequency flickering stimuli for all users. This study firstly proposes a strategy to adjust the stimuli frequency for each user that could cause better SSVEP. Moreover, to further enhance the SSVEP, this study incorporates flickering duty-cycle for stimuli design, which has been discussed less for SSVEP-based BCI systems. The proposed system consists of two modes, flicker frequency/duty-cycle selection mode and application mode. The flicker frequency/duty-cycle selection mode obtains two best frequencies between 24 and 36 Hz with their related optimal duty-cycle. Then the system goes into the application mode to control the devices. A new fact that has been found is that the optimal flicker frequency and duty-cycle do not vary with time. It means once the optical flicker frequency and duty-cycle is determined the first time, flicker frequency/duty-cycle selection mode does not need to operate the next time. Furthermore, the phase coding technology is used to extend the one command/one frequency to multi command/one frequency. Experimental results show the proposed system has good performance with average accuracy 95% and average command transfer interval 4.4925 s per command.
    其他題名: TNSRE
    其他題名: IEEE Trans Neural Syst Rehabil Eng
    出版者: United States: IEEE
    出版日期: 2013-09-01
    出處: IEEE transactions on neural systems and rehabilitation engineering, 2013-09, Vol.21 (5), p.697-703
    資源來源: IEEE Xplore
    識別號: ISSN: 1534-4320
    識別號: ISSN: 1558-0210
    識別號: EISSN: 1558-0210
    識別號: DOI: 10.1109/TNSRE.2013.2265308
    識別號: PMID: 23744702
    識別號: CODEN: ITNSB3
    顯示於類別:[電機工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML7檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明