資料載入中.....
|
請使用永久網址來引用或連結此文件:
https://ir.lib.ncu.edu.tw/handle/987654321/107185
|
| 題名: | Evaluate the Feasibility of Using Frontal SSVEP to Implement an SSVEP-Based BCI in Young, Elderly and ALS Groups |
| 作者: | 徐國鎧;Hsu, Hao-Teng;Lee, I-Hui;Tsai, Han-Ting;Chang, Hsiang-Chih;Shyu, Kuo-Kai;Hsu, Chuan-Chih;Chang, Hsiao-Huang;Yeh, Ting-Kuang;Chang, Chun-Yen;Lee, Po-Lei |
| 貢獻者: | 資訊電機學院電機工程學系 |
| 關鍵詞: | Adult;Aging;Amyotrophic lateral sclerosis;Amyotrophic lateral sclerosis (ALS);Amyotrophic Lateral Sclerosis - physiopathology;Amyotrophic Lateral Sclerosis - rehabilitation;brain-computer interface (BCI);Brain-Computer Interfaces;Calibration;Commands;Communication Aids for Disabled;Electrodes;electroencephalogram (EEG);Electroencephalography;Electroencephalography - methods;Evoked Potentials, Visual;Feasibility;Feasibility Studies;Frequency measurement;Frontal Lobe;Hospitals;Human-computer interface;Humans;Middle Aged;Patients;Psychomotor Performance;Rehabilitation;Reproducibility of Results;Senior citizens;Sensitivity and Specificity;steady-state visual evoked potential (SSVEP);Stimulation;Tasks;Visual Cortex - physiopathology;Visual Perception;Visualization |
| 日期: | 2016-05-01 |
| 上傳時間: | 2026-04-23 13:59:17 (UTC+8) |
| 出版者: | Institute of Electrical and Electronics Engineers Inc.;United States: IEEE |
| 摘要: | 摘要: This paper studies the amplitude-frequency characteristic of frontal steady-state visual evoked potential (SSVEP) and its feasibility as a control signal for brain computer interface (BCI). SSVEPs induced by different stimulation frequencies, from 13 ~ 31 Hz in 2 Hz steps, were measured in eight young subjects, eight elders and seven ALS patients. Each subject was requested to participate in a calibration study and an application study. The calibration study was designed to find the amplitude-frequency characteristics of SSVEPs recorded from Oz and Fpz positions, while the application study was designed to test the feasibility of using frontal SSVEP to control a two-command SSVEP-based BCI. The SSVEP amplitude was detected by an epoch-average process which enables artifact-contaminated epochs can be removed. The seven ALS patients were severely impaired, and four patients, who were incapable of completing our BCI task, were excluded from calculation of BCI performance. The averaged accuracies, command transfer intervals and information transfer rates in operating frontal SSVEP-based BCI were 96.1%, 3.43 s/command, and 14.42 bits/min in young subjects; 91.8%, 6.22 s/command, and 6.16 bits/min in elders; 81.2%, 12.14 s/command, and 1.51 bits/min in ALS patients, respectively. The frontal SSVEP could be an alternative choice to design SSVEP-based BCI. 其他題名: TNSRE 其他題名: IEEE Trans Neural Syst Rehabil Eng 出版者: United States: IEEE 出版日期: 2016-05-01 出處: IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2016-05, Vol.24 (5), p.603-615 資源來源: IEEE Xplore Digital Library 版權: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2016 識別號: ISSN: 1534-4320 識別號: ISSN: 1558-0210 識別號: EISSN: 1558-0210 識別號: DOI: 10.1109/TNSRE.2015.2496184 識別號: PMID: 26625417 識別號: CODEN: ITNSB3 |
| 顯示於類別: | [電機工程學系] 期刊論文
|
文件中的檔案:
| 檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
| index.html | | 0Kb | HTML | 20 | 檢視/開啟 |
|
在NCUIR中所有的資料項目都受到原著作權保護.
|