English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81834168      線上人數 : 2548
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/107484


    題名: Impedimetric detection of whole blood concentration for early detection of intraocular hemorrhage
    作者: 龔存雄;Gong, Cihun-Siyong Alex;Lei, Kin Fong;Hwang, Yih-Shiou;Zhang, Jia-Hua;Lei, Tim C.
    貢獻者: 資訊電機學院電機工程學系
    關鍵詞: Applied sciences;Biochip;Biological and medical sciences;Biotechnology;Blindness;Blood;Chips;Design. Technologies. Operation analysis. Testing;Electronics;Exact sciences and technology;Fundamental and applied biological sciences. Psychology;Hemorrhages;Impedimetric measurement;Implants;Integrated circuits;Intraocular hemorrhage;Methods. Procedures. Technologies;Miscellaneous;Others;Patients;Risk;Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices;Various methods and equipments;Whole blood
    日期: 2014-11-05
    上傳時間: 2026-04-23 14:14:16 (UTC+8)
    出版者: Elsevier;Amsterdam: Elsevier B.V
    摘要: 摘要: [Display omitted] •Development of a biochip for impedimetric measurement.•Determination of 5% (v/v) whole blood in intraocular irrigating solution by impedimetric detection.•Design of custom-made integrated circuit for intraocular implant chip.•Realization of self-monitor intraocular hemorrhage to prevent visual impairment and blindness in diabetes mellitus patients. Early detection of retinopathy can substantially reduce the risk of visual impairment and blindness in diabetes mellitus (DM) patients. Screening tool such as Amsler grid may be useful for the early detection of maculopathy in DM patients, but the metamorphopsia by Amsler gird self-screening is subjectively, not objectively. Although some kinds of optical imaging instruments have been used for the early detection of retinopathy, self-testing regularly is still not possible. In this work, impedimetric detection of whole blood concentration is proposed to be a promising technique to detect intraocular hemorrhage. An intraocular implant chip is also discussed to integrate the impedimetric detection into a CMOS IC. Results revealed that the impedimetric measurement could indicate 5% (v/v) whole blood in intraocular irrigating solution. Such technique is a label-free, non-invasive, and real-time analytical method. The preliminary results showed that impedimetric measurement had high potential to be implemented to an intraocular implant chip.
    出版者: Amsterdam: Elsevier B.V
    出版日期: 2014-11-05
    出處: Microelectronic engineering, 2014-11, Vol.129, p.70-76
    版權: 2014 Elsevier B.V.
    版權: 2015 INIST-CNRS
    識別號: ISSN: 0167-9317
    識別號: EISSN: 1873-5568
    識別號: DOI: 10.1016/j.mee.2014.07.020
    識別號: CODEN: MIENEF
    顯示於類別:[電機工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML19檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明