中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/107487
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82915358      在线人数 : 2323
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/107487


    题名: Impedimetric method for measuring ultra-low E. coli concentrations in human urine
    作者: 蔡章仁;Settu, Kalpana;Chen, Ching-Jung;Liu, Jen-Tsai;Chen, Chien-Lung;Tsai, Jang-Zern
    贡献者: 資訊電機學院電機工程學系
    关键词: Bacteria;bacterial adhesion;Biofilm;Biofilms;Biosensing Techniques - methods;Biosensors;Capacitance;Electric circuits;Electric Impedance;Electrochemical impedance spectroscopy;Electrodes;electronic circuits;Escherichia coli;Escherichia coli - isolation & purification;gold;Gold - chemistry;Human;Humans;Impedance;Interdigitated microelectrode;microbial growth;Microelectrodes;Sensors;urinary tract diseases;Urinary tract infection (UTI);Urine;Urine - microbiology
    日期: 2015-04-05
    上传时间: 2026-04-23 14:14:21 (UTC+8)
    出版者: Elsevier Ltd.;England: Elsevier B.V
    摘要: 摘要: In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R2>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×100 to 7×108 cells/ml, in urine samples with high sensitivity. •This study reports the possibility of detecting E. coli in urine samples using interdigitated microelectrode sensor.•Ultra-low E. coli concentration was measured in urine by growth time-graded impedance monitoring approach.•Sensor was capable of detecting larger range of E. coli concentrations at various growth times.•Merits of the method include easy fabrication, low-cost and user-friendly.
    其他題名: Biosens Bioelectron
    出版者: England: Elsevier B.V
    出版日期: 2015-04-15
    出處: Biosensors & bioelectronics, 2015-04, Vol.66, p.244-250
    版權: 2014 Elsevier B.V.
    版權: Copyright © 2014 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0956-5663
    識別號: ISSN: 1873-4235
    識別號: EISSN: 1873-4235
    識別號: DOI: 10.1016/j.bios.2014.11.027
    識別號: PMID: 25437359
    显示于类别:[電機工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML19检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明