中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/107527
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94201/94201 (100%)
造访人次 : 81594857      在线人数 : 3327
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/107527


    题名: Independence of amplitude-frequency and phase calibrations in an SSVEP-based BCI using stepping delay flickering sequences
    作者: 李柏磊;Chang, Hsiang-Chih;Lee, Po-Lei;Lo, Men-Tzung;Lee, I.-Hui;Yeh, Ting-Kuang;Chang, Chun-Yen
    贡献者: 資訊電機學院電機工程學系
    关键词: Accuracy;Adult;Algorithms;Analog-Digital Conversion;Brain - physiology;Brain-computer interface (BCI);Calibration;Delay;Electrodes;Electroencephalography;electroencephalography (EEG);Evoked Potentials, Visual - physiology;Female;Fixation, Ocular;Fourier Analysis;Humans;Male;Online Systems;Photic Stimulation - methods;Psychomotor Performance - physiology;Registers;Signal Processing, Computer-Assisted;Silicon;steady-state visual evoked potential (SSVEP);stepping delay flickering sequence (SDFS);User-Computer Interface;Visualization;Young Adult
    日期: 2012-05-31
    上传时间: 2026-04-23 14:16:31 (UTC+8)
    出版者: Institute of Electrical and Electronics Engineers Inc.;United States: IEEE
    摘要: 摘要: This study proposes a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) independent of amplitude-frequency and phase calibrations. Six stepping delay flickering sequences (SDFSs) at 32-Hz flickering frequency were used to implement a six-command BCI system. EEG signals recorded from Oz position were first filtered within 29-35 Hz, segmented based on trigger events of SDFSs to obtain SDFS epochs, and then stored separately in epoch registers. An epoch-average process suppressed the inter-SDFS interference. For each detection point, the latest six SDFS epochs in each epoch register were averaged and the normalized power of averaged responses was calculated. The visual target that induced the maximum normalized power was identified as the visual target. Eight subjects were recruited in this study. All subjects were requested to produce the "563241" command sequence four times. The averaged accuracy, command transfer interval, and information transfer rate (mean std.) values for all eight subjects were 97.38 5.97%, 3.56 0.68 s, and 42.46 11.17 bits/min, respectively. The proposed system requires no calibration in either the amplitude-frequency characteristic or the reference phase of SSVEP which may provide an efficient and reliable channel for the neuromuscular disabled to communicate with external environments.
    其他題名: TNSRE
    其他題名: IEEE Trans Neural Syst Rehabil Eng
    出版者: United States: IEEE
    出版日期: 2012-05-01
    出處: IEEE transactions on neural systems and rehabilitation engineering, 2012-05, Vol.20 (3), p.305-312
    資源來源: IEEE Electronic Library (IEL)
    版權: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) May 2012
    識別號: ISSN: 1534-4320
    識別號: ISSN: 1558-0210
    識別號: EISSN: 1558-0210
    識別號: DOI: 10.1109/TNSRE.2011.2180925
    識別號: PMID: 22203724
    識別號: CODEN: ITNSB3
    显示于类别:[電機工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML17检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明