English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94274/94274 (100%)
造訪人次 : 82872819      線上人數 : 2202
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/107943


    題名: Microelectrodes with gold nanoparticles and self-assembled monolayers for in vivo recording of striatal dopamine
    作者: 黃英儒;Tsai, Tien-Chun;Guo, Chun-Xian;Han, Huan-Zhang;Li, Yu-Ting;Huang, Ying-Zu;Li, Chang-Ming;Chen, Jia-Jin Jason
    貢獻者: 生醫理工學院認知神經科學研究所
    日期: 2012-06-21
    上傳時間: 2026-04-23 14:29:17 (UTC+8)
    出版者: Royal Society of Chemistry
    摘要: 摘要: Electrochemical determination of in vivo dopamine (DA) using implantable microelectrodes is essential for monitoring the DA depletion of an animal model of Parkinson's disease (PD), but faces substantial interference from ascorbic acid (AA) in the brain area due to similar electroactive characteristics. This study utilizes gold nanoparticles (Au-NPs) and self-assembled monolayers (SAMs) to modify platinum microelectrodes for improving sensitivity and specificity to DA and alleviating AA interference. With appropriate choice of ω-mercaptoalkane carboxylic acid chain length, our results show that a platinum microelectrode coated with Au-NPs and 3-mercaptopropionic acid (MPA) has approximately an 881-fold specificity to AA. During amperometric measurements, Au-NP/MPA reveals that the responsive current is linearly dependent on DA over the range of 0.01-5 μM with a correlation coefficient of 0.99 and the sensitivity is 2.7-fold that of a conventional Nafion-coated electrode. Other important features observed include fast response time (below 2 s), resistance to albumin adhesion and low detection limit (7 nM) at a signal to noise ratio of 3. Feasibility of in vivo DA recording with the modified microelectrodes is verified by real-time monitoring of electrically stimulated DA release in the striatum of anesthetized rats with various stimulation parameters and administration of a DA uptake inhibitor. The developed microelectrodes present an attractive alternative to the traditional options for continuous electrochemical in vivo DA monitoring. Modification of platinum microelectrodes using gold nanoparticles and self-assembled monolayers for dopamine sensing in the brains of rats.
    出版日期: 2012-05-21
    資源來源: Royal Society of Chemistry
    識別號: ISSN: 0003-2654
    識別號: EISSN: 1364-5528
    識別號: DOI: 10.1039/c2an16306c
    顯示於類別:[認知與神經科學研究所 ] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML15檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明