中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108215
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 94201/94201 (100%)
Visitors : 81671788      Online Users : 2658
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: https://ir.lib.ncu.edu.tw/handle/987654321/108215


    Title: A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant
    Authors: 潘敏俊;Pan, Min-Chun;Zhuang, Han-Bo;Chen, Chin-Sung;Wu, Jer-Whey;Lee, Shyh-Yuan
    Contributors: 工學院機械工程學系
    Keywords: Bone and Bones - physiology;Dental implant;Dental Implants;Interfacial bone defect;Materials Testing - methods;Noncontact detection;Osseointegration;Radiology;Resonance frequency analysis
    Date: 2013-12-01
    Issue Date: 2026-04-23 14:39:20 (UTC+8)
    Publisher: Elsevier BV;England: Elsevier Ltd
    Abstract: 摘要: This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired with a capacitance sensor. The spectral analysis was used to characterize the first RF value. Two types of in vitro defect models, Buccal-Lingual (BL) and Mesial-Distal (MD), were constructed for the verification. The measurements of the RF for a defect model clamped at four different heights (9, 10, 11, and 12mm) were performed in two sensing directions (BL and MD). Moreover, each model was also analyzed using an Osstell Mentor. The obtained two parameters, RF and ISQ (Implant Stability Quotient), were statistically analyzed through one-way analysis of variance (ANOVA) and linear regression analysis for comparisons. The RF and the ISQ values obtained for all of the defect models at the four clamp heights decreased significantly (p<0.05) with an increase in the severity of the defect. The two parameters for each imperfection increase significantly (p<0.05) with an increase in the clamp height. Additionally, the RFs of all of the defect models are linearly correlated with their corresponding ISQs for the four clamp heights and the two measuring orientations. Therefore, our developed technique is feasible for the assessment of the postoperative healing around a dental implant.
    其他題名: Med Eng Phys
    出版者: England: Elsevier Ltd
    出版日期: 2013-12-01
    出處: Medical engineering & physics, 2013-12, Vol.35 (12), p.1825-1830
    版權: 2013 IPEM
    版權: IPEM
    版權: Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
    識別號: ISSN: 1350-4533
    識別號: ISSN: 1873-4030
    識別號: EISSN: 1873-4030
    識別號: DOI: 10.1016/j.medengphy.2013.05.006
    識別號: PMID: 23764430
    Appears in Collections:[Departmant of Mechanical Engineering ] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML25View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明