English
| 正體中文 |
简体中文
|
全文筆數/總筆數 : 94274/94274 (100%)
造訪人次 : 82906533 線上人數 : 2378
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by
NTU Library IR team.
搜尋範圍
全部NCUIR
工學院
機械工程學系
--期刊論文
查詢小技巧:
您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
進階搜尋
主頁
‧
登入
‧
上傳
‧
說明
‧
關於NCUIR
‧
管理
NCU Institutional Repository
>
工學院
>
機械工程學系
>
期刊論文
>
Item 987654321/108409
資料載入中.....
書目資料匯出
Endnote RIS 格式資料匯出
Bibtex 格式資料匯出
引文資訊
資料載入中.....
資料載入中.....
請使用永久網址來引用或連結此文件:
https://ir.lib.ncu.edu.tw/handle/987654321/108409
題名:
Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system
作者:
曾清秀
;
Chen, Chun-Ming
;
Cheng, Chih-Ting
;
Lin, Cheng-Shou
;
Lin, Shang-Chih
;
Chiang, Chien-Chung
;
Luo, Chu-An
;
Tseng, Ching-Shiow
貢獻者:
工學院機械工程學系
關鍵詞:
Arthroplasty, Replacement, Hip - instrumentation
;
Biomechanical Phenomena - physiology
;
Bone Screws
;
Equipment Failure Analysis
;
Femur Head
;
Femur Neck
;
Finite Element Analysis
;
Finite-element
;
Hip nonstemmed
;
Hip Prosthesis
;
Humans
;
Internal Fixators
;
Male
;
Muscle Contraction
;
Neck cup
;
Physical Medicine and Rehabilitation
;
Prosthesis Design - methods
;
Prosthesis Failure
;
Screw breakage
;
Stress, Mechanical
;
Stress-shielding
;
Weight-Bearing
;
Young Adult
日期:
2014-02-01
上傳時間:
2026-04-23 14:46:54 (UTC+8)
出版者:
Elsevier Ltd.;England: Elsevier Ltd
摘要:
摘要: Some nonstemmed hip systems have been developed to avoid stress shielding and aseptic loosening, which are major drawbacks of stemmed hip arthroplasty. Without the stem, the cup over the femoral head can be stabilized by anatomic fitness of the cup interior and mechanical fixation of the auxiliary screws. Using finite-element method, neck-shaped systems with two bone-cup fitness situations and four types of screw breakages are systematically investigated to evaluate their biomechanical effects on construct performances. The construct stresses and interfacial micromotion were chosen for comparison between two bone-cup fitness situations and four types of screw breakages. The screw breakage deteriorates the stresses of the mating screw and the neck cup and loosens the bone-cup interfaces. The breakages of central and locking screws decrease the bone stress by about 43.2% and 12.7%, respectively. This indicates that the central screw is a more effective load-bearer for the superimposed cup than the locking screw. As compared with the fitting cup, the stress of cup and the bone stresses of the unfitting cup obviously increase. This demonstrates that the load-transferring path at the cup bottom is important in directly relieving the prosthetic stresses. Any screw design inducing stress concentration should be validated to avoid screw breakage. Comparatively, surgical unfitness has a more significant effect on the construct performance than does the screw breakage. Even for custom-made cups, cautious preparation of the neck resection is still necessary to ensure intimate bone-cup contact.
其他題名: Clin Biomech (Bristol, Avon)
出版者: England: Elsevier Ltd
出版日期: 2014-02-01
出處: Clinical biomechanics (Bristol), 2014-02, Vol.29 (2), p.161-169
版權: 2013
版權: Copyright © 2013. Published by Elsevier Ltd.
識別號: ISSN: 0268-0033
識別號: ISSN: 1879-1271
識別號: EISSN: 1879-1271
識別號: DOI: 10.1016/j.clinbiomech.2013.11.017
識別號: PMID: 24418222
顯示於類別:
[機械工程學系] 期刊論文
文件中的檔案:
檔案
描述
大小
格式
瀏覽次數
index.html
0Kb
HTML
12
檢視/開啟
在NCUIR中所有的資料項目都受到原著作權保護.
社群 sharing
::: Copyright National Central University. | 國立中央大學圖書館版權所有 |
收藏本站
|
設為首頁
| 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
DSpace Software
Copyright © 2002-2004
MIT
&
Hewlett-Packard
/
Enhanced by
NTU Library IR team
Copyright ©
-
隱私權政策聲明