    題名: Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system
    作者: 曾清秀;Chen, Chun-Ming;Cheng, Chih-Ting;Lin, Cheng-Shou;Lin, Shang-Chih;Chiang, Chien-Chung;Luo, Chu-An;Tseng, Ching-Shiow
    貢獻者: 工學院機械工程學系
    關鍵詞: Arthroplasty, Replacement, Hip - instrumentation;Biomechanical Phenomena - physiology;Bone Screws;Equipment Failure Analysis;Femur Head;Femur Neck;Finite Element Analysis;Finite-element;Hip nonstemmed;Hip Prosthesis;Humans;Internal Fixators;Male;Muscle Contraction;Neck cup;Physical Medicine and Rehabilitation;Prosthesis Design - methods;Prosthesis Failure;Screw breakage;Stress, Mechanical;Stress-shielding;Weight-Bearing;Young Adult
    日期: 2014-02-01
    上傳時間: 2026-04-23 14:46:54 (UTC+8)
    出版者: Elsevier Ltd.;England: Elsevier Ltd
    摘要: 摘要: Some nonstemmed hip systems have been developed to avoid stress shielding and aseptic loosening, which are major drawbacks of stemmed hip arthroplasty. Without the stem, the cup over the femoral head can be stabilized by anatomic fitness of the cup interior and mechanical fixation of the auxiliary screws. Using finite-element method, neck-shaped systems with two bone-cup fitness situations and four types of screw breakages are systematically investigated to evaluate their biomechanical effects on construct performances. The construct stresses and interfacial micromotion were chosen for comparison between two bone-cup fitness situations and four types of screw breakages. The screw breakage deteriorates the stresses of the mating screw and the neck cup and loosens the bone-cup interfaces. The breakages of central and locking screws decrease the bone stress by about 43.2% and 12.7%, respectively. This indicates that the central screw is a more effective load-bearer for the superimposed cup than the locking screw. As compared with the fitting cup, the stress of cup and the bone stresses of the unfitting cup obviously increase. This demonstrates that the load-transferring path at the cup bottom is important in directly relieving the prosthetic stresses. Any screw design inducing stress concentration should be validated to avoid screw breakage. Comparatively, surgical unfitness has a more significant effect on the construct performance than does the screw breakage. Even for custom-made cups, cautious preparation of the neck resection is still necessary to ensure intimate bone-cup contact.
    其他題名: Clin Biomech (Bristol, Avon)
    出版者: England: Elsevier Ltd
    出版日期: 2014-02-01
    出處: Clinical biomechanics (Bristol), 2014-02, Vol.29 (2), p.161-169
    版權: 2013
    版權: Copyright © 2013. Published by Elsevier Ltd.
    識別號: ISSN: 0268-0033
    識別號: ISSN: 1879-1271
    識別號: EISSN: 1879-1271
    識別號: DOI: 10.1016/j.clinbiomech.2013.11.017
    識別號: PMID: 24418222
    顯示於類別:[機械工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML12檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明