中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108416
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82915388      在线人数 : 2294
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108416


    题名: Biomechanical effects of plate area and locking screw on medial open tibial osteotomy
    作者: 曾清秀;Luo, Chu-An;Lin, Shang-Chih;Hwa, Su-Yang;Chen, Chun-Ming;Tseng, Ching-Shiow
    贡献者: 工學院機械工程學系
    关键词: Biomechanical Phenomena;Bone Plates;Bone Screws;finite-element analysis;high tibial osteotomy;Humans;knee;locking screw;Osteoarthritis, Knee - surgery;Osteotomy - methods;plate;Tibia - physiology;Tibia - surgery;Tomography, X-Ray Computed
    日期: 2015-09-10
    上传时间: 2026-04-23 14:47:13 (UTC+8)
    出版者: Informa Healthcare;England: Taylor & Francis
    摘要: 摘要: Medial open high tibial osteotomy (HTO) has been used to treat osteoarthritis of the medial compartment of the knee. However, weaker plate strength, unstable plate/screw junction and improper surgery technique are highly related to the HTO outcomes. Two π-shape plates were designed and eight variations (two supporting area × four locking stiffness) were compared by finite-element method. The computed tomography-based tibia was reconstructed and both wedge micromotion and implant stresses were chosen as the comparison indices. The construct was subjected to surgical and physiological loads. The medial-posterior region is the most loaded region and the load through the posterior leg is about four times that through the anterior leg. This indicates that the two-leg design can form a force-couple mechanism to effectively reduce the implant stresses. The use of locking screws significantly decrease the screw and hole stresses. However, the extending plate reduces the stresses of screws and holes above the wedge but makes the distal screws and holes much stressed. Wedge micromotion is affected by extending plate rather than locking screw. Three factors contribute to effective stabilisation of unstable HTO wedge: (1) intimate tibia-plate contact at medial-posterior regions, (2) sufficient rigidity at plate-screw junctions and (3) effective moment-balancing design at distal tibia-plate interfaces.
    其他題名: Comput Methods Biomech Biomed Engin
    出版者: England: Taylor & Francis
    出版日期: 2015-09-10
    出處: Computer methods in biomechanics and biomedical engineering, 2015-09, Vol.18 (12), p.1263-1271
    版權: 2014 Taylor & Francis 2014
    識別號: ISSN: 1025-5842
    識別號: ISSN: 1476-8259
    識別號: EISSN: 1476-8259
    識別號: DOI: 10.1080/10255842.2014.895335
    識別號: PMID: 24617553
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML20检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明