中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108470
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 94274/94274 (100%)
Visitors : 82911042      Online Users : 2181
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: https://ir.lib.ncu.edu.tw/handle/987654321/108470


    Title: Clinical pedicle screw insertion trials and system improvement of C-arm image navigation system
    Authors: 曾清秀;Chang, Chih-Ju;Yu, Ching-Hsiao;Lin, Geng-Li;Tse, Alex;Chu, Hong-Yu;Tseng, Ching-Shiow
    Contributors: 工學院機械工程學系
    Keywords: Biomedical Engineering and Bioengineering;Cell Biology;Engineering;Imaging;Original Article;Radiology
    Date: 2016-02-01
    Issue Date: 2026-04-23 14:50:56 (UTC+8)
    Publisher: Springer International Publishing AG;Berlin/Heidelberg: Springer Berlin Heidelberg
    Abstract: 摘要: C-arm-image-assisted navigation systems for orthopedic surgery have been applied clinically for several years. Pedicle screw implantation is one of the important applications. A precise definition of a C-arm X-ray projection model is the key requirement for a C-arm-assisted navigation system. This study proposes using a high-pass filter to extract the contour of large markers of the image calibrator and an adaptive threshold method to segment images of small markers, thus improving the overall recognition rate of markers and enhancing the robustness of image calibration. A method for time synchronization of X-ray imaging and the detection of a patient’s lumbar position data for respiration compensation is also proposed. Positioning accuracy evaluation of the developed C-arm-assisted navigation system was carried out clinically. The results show that the mean positioning error is 2.409 mm and that the mean direction error is 1.449°.
    其他題名: J. Med. Biol. Eng
    出版者: Berlin/Heidelberg: Springer Berlin Heidelberg
    出版日期: 2016-02
    出處: Journal of medical and biological engineering, 2016-02, Vol.36 (1), p.44-52
    版權: Taiwanese Society of Biomedical Engineering 2016
    識別號: ISSN: 1609-0985
    識別號: EISSN: 2199-4757
    識別號: DOI: 10.1007/s40846-016-0107-2
    Appears in Collections:[Departmant of Mechanical Engineering ] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML16View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明