    Title: Effect of coating layer thickness for boiling heat transfer on micro porous coated surface in confined and unconfined spaces
    Authors: 楊建裕;Yang, Chien-Yuh;Liu, Chien-Fu
    Contributors: 工學院機械工程學系
    Keywords: Applied sciences;Boiling;Boiling heat transfer;Coating;Confined environments;Confined space;Cooling;Design. Technologies. Operation analysis. Testing;Electronics;Exact sciences and technology;Heat exchangers;Heat flux;Heat transfer;Heat transfer coefficients;Integrated circuits;Micro porous coating;Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices;Surface chemistry
    Date: 2013-05-01
    Issue Date: 2026-04-23 15:01:21 (UTC+8)
    Publisher: Elsevier Inc.;Amsterdam: Elsevier Inc
    Abstract: 摘要: Attributed to its high heat transfer coefficient, evaporating cooling involving the use of micro heat exchangers is considered a possible thermal management solution for cooling of high heat flux electronic devices. The boiling heat transfer in micro heat exchangers is generally confined in a very narrow space. The heat transfer characteristics are indeed different from those of conventional unconfined boiling. This work provides an experimental analysis of the boiling heat transfer of methanol on plain and micro porous coated surfaces inside confined space. Five micro porous coating surfaces with thicknesses of 81, 109, 150, 182 and 225μm were tested in confined and unconfined spaces. Effects of space confinement, coating layer thickness and heat flux on the heat transfer coefficient and critical heat flux were discussed. The micro porous coating layer provides large amount of active nucleation sites that significantly enhances heat transfer coefficients up to a factor of 4.5 in comparing to that on plain surface. But the porous coating layer also exerts higher bubble leaving resistance and coating layer thermal resistance. The combination of these three effects brought about an optimum coating layer thickness for micro porous surfaces in both confined and unconfined spaces.
    出版者: Amsterdam: Elsevier Inc
    出版日期: 2013-05-01
    出處: Experimental thermal and fluid science, 2013-05, Vol.47, p.40-47
    版權: 2013 Elsevier Inc.
    版權: 2014 INIST-CNRS
    識別號: ISSN: 0894-1777
    識別號: EISSN: 1879-2286
    識別號: DOI: 10.1016/j.expthermflusci.2013.01.001
    Appears in Collections:[機械工程學系] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML18View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明