English
| 正體中文 |
简体中文
|
全文筆數/總筆數 : 94274/94274 (100%)
造訪人次 : 82906530 線上人數 : 2375
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by
NTU Library IR team.
搜尋範圍
全部NCUIR
工學院
機械工程學系
--期刊論文
查詢小技巧:
您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
進階搜尋
主頁
‧
登入
‧
上傳
‧
說明
‧
關於NCUIR
‧
管理
NCU Institutional Repository
>
工學院
>
機械工程學系
>
期刊論文
>
Item 987654321/108708
資料載入中.....
書目資料匯出
Endnote RIS 格式資料匯出
Bibtex 格式資料匯出
引文資訊
資料載入中.....
資料載入中.....
請使用永久網址來引用或連結此文件:
https://ir.lib.ncu.edu.tw/handle/987654321/108708
題名:
Effect of slippage on the thermocapillary migration of a small droplet
作者:
陳志臣
;
Nguyen, Huy-Bich
;
Chen, Jyh-Chen
貢獻者:
工學院機械工程學系
關鍵詞:
Special Topic: Selected Papers from the Second Conference on Advances in Microfluidics and Nanofluidics and Asia-Pacific International Symposium on Lab on Chip, Singapore, 2011 (Guest Editors: Zhiping Wang and Charles Yan Chun)
日期:
2012-03-02
上傳時間:
2026-04-23 15:02:47 (UTC+8)
出版者:
American Institute of Physics;United States: American Institute of Physics
摘要:
摘要: We conduct a numerical investigation and analytical analysis of the effect of slippage on the thermocapillary migration of a small liquid droplet on a horizontal solid surface. The finite element method is employed to solve the Navier-Stokes equations coupled with the energy equation. The effect of the slip behavior on the droplet migration is determined by using the Navier slip condition at the solid-liquid boundary. The results indicate that the dynamic contact angles and the contact angle hysteresis of the droplet are strictly correlated to the slip coefficient. The enhancement of the slip length leads to an increase in the droplet migration velocity due to the enhancement of the net momentum of thermocapillary convection vortices inside the droplet. A larger contact angle leads to an increase in the migration velocity which in turn enlarges the rate of the droplet migration velocity to the slip length. There is good agreement between the analytical and the numerical results when the dynamic contact angle utilizes in the analytical approach obtained from the results of the numerical computation, and the static contact angle is smaller than 50°.
其他題名: Biomicrofluidics
出版者: United States: American Institute of Physics
出版日期: 2012-03-01
出處: Biomicrofluidics, 2012-03, Vol.6 (1), p.012809-012809-13
資源來源: AIP Journals (American Institute of Physics)
版權: American Institute of Physics
版權: 2012 American Institute of Physics
版權: Copyright © 2012 American Institute of Physics 2012 American Institute of Physics
識別號: ISSN: 1932-1058
識別號: EISSN: 1932-1058
識別號: DOI: 10.1063/1.3644382
識別號: PMID: 22662076
識別號: CODEN: BIOMGB
顯示於類別:
[機械工程學系] 期刊論文
文件中的檔案:
檔案
描述
大小
格式
瀏覽次數
index.html
0Kb
HTML
11
檢視/開啟
在NCUIR中所有的資料項目都受到原著作權保護.
社群 sharing
::: Copyright National Central University. | 國立中央大學圖書館版權所有 |
收藏本站
|
設為首頁
| 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
DSpace Software
Copyright © 2002-2004
MIT
&
Hewlett-Packard
/
Enhanced by
NTU Library IR team
Copyright ©
-
隱私權政策聲明