中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/108762
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82915388      在线人数 : 2294
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108762


    题名: Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant
    作者: 曾清秀;Chen, Chun-Ming;Tsai, Wen-Chi;Lin, Shang-Chih;Tseng, Ching-Shiow
    贡献者: 工學院機械工程學系
    关键词: Analysis;Arthroplasty, Replacement, Hip - instrumentation;Arthroplasty, Replacement, Hip - methods;Biomechanics;Bone surgery;Comparative analysis;Computer software industry;Epidemiology;Femur - diagnostic imaging;Femur Head - diagnostic imaging;Finite Element Analysis;Hip Joint - diagnostic imaging;Humans;Interfaces;Internal Medicine;Load;Male;Medicine;Medicine & Public Health;Musculoskeletal diseases;Orthopedics;Orthopedics and biomechanics;Prosthesis Design - methods;Radiography;Rehabilitation;Research Article;Rheumatology;Sports Medicine;Stress, Mechanical;Transplants & implants;Young Adult
    日期: 2014-09-26
    上传时间: 2026-04-23 15:04:38 (UTC+8)
    出版者: London: BioMed Central
    摘要: 摘要: Background Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. Methods In this study, the finite-element models of one intact, one stemmed, and two nonstemmed femora with minimal removal of the healthy neck were investigated to evaluate their biomechanical effects. The resurfacing (ball-shaped) and fitting (neck-shaped) systems were respectively selected as the representative of the ready- and custom-made nonstemmed implants. The stress distribution and interface micromotion were selected as the comparison indices. Results The results showed that stress distributions of the two nonstemmed femora are consistently more similar to the intact femur than the stemmed one. Around the proximal femur, the stem definitely induces the stress-shielding phenomenon of its counterparts. The fitting system with the anatomy-shaped cup can make intimate contact with the neck cortex and reduce the bone-cup micromotion and the implant stress. Comparatively, the reamed femoral head provides weaker support to the resurfacing cup causing higher interfacial micromotion. Conclusions The reserved femoral neck could act as the load-transferring medium from the acetabular cup, femoral neck, to the diaphysial bone, thus depressing the stress-shielding effect below the neck region. If the hip-cup construct can be definitely stabilized, the nonstemmed design could be an alternative of hip arthroplasty for the younger or the specific patients with the disease limited only to the femoral head.
    其他題名: BMC Musculoskelet Disord
    出版者: London: BioMed Central
    出版日期: 2014-09-26
    出處: BMC musculoskeletal disorders, 2014-09, Vol.15 (1), p.312-312, Article 312
    資源來源: EBSCOhost Academic Search Premier
    版權: Chen et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver ( ) applies to the data made available in this article, unless otherwise stated.
    版權: COPYRIGHT 2014 BioMed Central Ltd.
    版權: 2014 Chen et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
    版權: Chen et al.; licensee BioMed Central Ltd. 2014
    識別號: ISSN: 1471-2474
    識別號: EISSN: 1471-2474
    識別號: DOI: 10.1186/1471-2474-15-312
    識別號: PMID: 25257699
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML22检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明