    題名: Flexible micro sensors for in-situ diagnosis of proton exchange membrane fuel cell
    作者: 李雄;Chen, Chia-Hung;Lee, Chi-Yuan;Lee, Shyong;Liu, Yun-Min
    貢獻者: 工學院機械工程學系
    關鍵詞: Alternative fuels. Production and utilization;Applied sciences;Deviation;Diagnosis;Energy;Exact sciences and technology;Exchange;Flow rate;Fuel cells;Fuels;Hydrogen;Membranes;MEMS;Micro flexible sensors;PEMFC;Sensors;Upstream
    日期: 2014-01-01
    上傳時間: 2026-04-23 15:11:44 (UTC+8)
    出版者: Elsevier Ltd.;Kidlington: Elsevier Ltd
    摘要: 摘要: The temperature and flooding phenomenon during operation can strongly influence a proton exchange membrane fuel cell (PEMFC) performance. Non-uniform conditions exist in each segment of fuel cell. Previous studies have investigated these conditions on the mm scale using destructive methods or simulation, but none has been able to obtain exact data from within the fuel cell. This research applies micro-electro-mechanical systems (MEMS) to develop a flexible micro temperature, pressure and flow sensor. It is composed of main two parts: 1. Fabrication of flexible micro sensors on polyimide (PI) film by MEMS; 2. Embedding flexible micro sensors into a PEMFC for in-situ diagnosis and performance. Internal temperature data demonstrate that the downstream exceeds upstream and midstream, because the generated heat is carried by gas from the inlet and downstream, where it undergoes a severe reaction. Monitoring the inner pressure for a long period revealed that the accumulation and elimination of water in flow field may be responsible for increased pressure and the recovery. The flow rate that is supplied by the flow controller in the testing system exceeds those measured by the upstream and downstream sensors. This deviation is consistent with the results of a fuel cell leak test. •To develop the flexible micro sensors for in-situ diagnosis in a PEM fuel cell.•The flexible micro sensors are: (1) small; (2) highly sensitive; (3) in situ measurement.•Monitoring the distribution of the temperature, pressure and flow can stabilize fuel cell performance.
    出版者: Kidlington: Elsevier Ltd
    出版日期: 2014-10-31
    出處: International journal of hydrogen energy, 2014-10, Vol.39 (32), p.18337-18342
    資源來源: Elsevier ScienceDirect Journals Complete
    版權: 2014 Hydrogen Energy Publications, LLC.
    版權: 2015 INIST-CNRS
    識別號: ISSN: 0360-3199
    識別號: EISSN: 1879-3487
    識別號: DOI: 10.1016/j.ijhydene.2014.08.151
    識別號: CODEN: IJHEDX