English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81626064      線上人數 : 3340
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108967


    題名: Modified Fabry-Perot interferometer for displacement measurement in ultra large measuring range
    作者: 董必正;Chang, Chung-Ping;Tung, Pi-Cheng;Shyu, Lih-Horng;Wang, Yung-Cheng;Manske, Eberhard
    貢獻者: 工學院機械工程學系
    日期: 2013-05-01
    上傳時間: 2026-04-23 15:18:15 (UTC+8)
    出版者: United States: AIP Publishing
    摘要: 摘要: Laser interferometers have demonstrated outstanding measuring performances for high precision positioning or dimensional measurements in the precision industry, especially in the length measurement. Due to the non-common-optical-path structure, appreciable measurement errors can be easily induced under ordinary measurement conditions. That will lead to the limitation and inconvenience for in situ industrial applications. To minimize the environmental and mechanical effects, a new interferometric displacement measuring system with the common-optical-path structure and the resistance to tilt-angle is proposed. With the integration of optomechatronic modules in the novel interferometric system, the resolution up to picometer order, high precision, and ultra large measuring range have been realized. For the signal stabilization of displacement measurement, an automatic gain control module has been proposed. A self-developed interpolation model has been employed for enhancing the resolution. The novel interferometer can hold the advantage of high resolution and large measuring range simultaneously. By the experimental verifications, it has been proven that the actual resolution of 2.5 nm can be achieved in the measuring range of 500 mm. According to the comparison experiments, the maximal standard deviation of the difference between the self-developed Fabry-Perot interferometer and the reference commercial Michelson interferometer is 0.146 μm in the traveling range of 500 mm. With the prominent measuring characteristics, this should be the largest dynamic measurement range of a Fabry-Perot interferometer up till now.
    其他題名: Rev Sci Instrum
    出版者: United States: AIP Publishing
    出版日期: 2013-05-01
    出處: Review of Scientific Instruments, 2013-05, Vol.84 (5), p.053105
    資源來源: AIP Journals (American Institute of Physics)
    版權: AIP Publishing LLC
    識別號: ISSN: 0034-6748
    識別號: ISSN: 1089-7623
    識別號: EISSN: 1089-7623
    識別號: DOI: 10.1063/1.4803672
    識別號: PMID: 23742530
    識別號: CODEN: RSINAK
    顯示於類別:[機械工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML15檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明