    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/109034


    题名: Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery
    作者: 曾清秀;Chu, Hong-Yu;Tse, Alex;Lin, Geng-Li;Chang, Chih-Ju;Tseng, Ching-Shiow
    贡献者: 工學院機械工程學系
    日期: 2015-01-01
    上传时间: 2026-04-23 15:25:58 (UTC+8)
    出版者: Hindawi Limited;Cairo, Egypt: Hindawi Publishing Corporation
    摘要: 摘要: C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR) images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.
    其他題名: Appl Bionics Biomech
    出版者: Cairo, Egypt: Hindawi Publishing Corporation
    出版日期: 2015-01-01
    出處: Applied Bionics and Biomechanics, 2015-01, Vol.2015 (2015), p.1-9
    資源來源: Publicly available content database
    版權: Copyright © 2015 Chih-Ju Chang et al.
    版權: Copyright © 2015 Chih-Ju Chang et al. 2015
    識別號: ISSN: 1176-2322
    識別號: ISSN: 1754-2103
    識別號: EISSN: 1754-2103
    識別號: DOI: 10.1155/2015/478062
    識別號: PMID: 27018859
    显示于类别:[Departmant of Mechanical Engineering ] journal & Dissertation

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML13检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明