    題名: Spherical wrist dimensional synthesis adapted for tool-guidance medical robots
    作者: 伊泰龍;Essomba, T.;Nouaille, L.;Laribi, Med Amine;Nelson, C.A.;Zeghloul, S.;Poisson, G.
    貢獻者: 工學院機械工程學系
    關鍵詞: Automatic;dimensional synthesis;Engineering Sciences;optimization;spherical parallel manipulator;spherical serial robot;Tool-guidance medical robot
    日期: 2014-01-01
    上傳時間: 2026-04-23 15:28:06 (UTC+8)
    出版者: EDP Sciences;Villeurbanne: EDP Sciences
    摘要: 摘要: The objective of this article is to present the dimensional synthesis of serial and parallel spherical wrists, an important step in the design process of medical robots. This step is carried out to obtain optimal dimensions of tool-guidance medical robots. With this goal, we have first studied the specifications of two robots with different medical applications: one for tele-echography examination and one for minimally invasive surgery. Then, we have established that the medical needs expressed by the doctors were very different but the specifications in robotic terms have a lot of common points (kinematics, workspace, bulkiness). For both applications studied, robots need a mobility of three rotations around a fixed point (probe contact point on the patient’s skin or trocar incision). So, a spherical wrist architecture is adapted to their needs. An important constraint related to medical applications is that the robot must be compact in order to not obstruct or collide with its environment (medical personnel or patient). We perform dimensional synthesis allowing determination of dimensions of the mechanism for serial and parallel spherical wrists, for a tele-echography robot, and a serial wrist for a minimally invasive surgery robot. We use multi-criteria optimization methods minimizing a cost function to obtain both good kinematic performance and compactness for the architecture. The difficulty/challenge of this design process, depending of the studied applications, is the choice of efficient criteria describing the performances and the constraints of the robot. The design variables must faithfully represent the specifications of the robot so that its performance can respond to the medical requirements. We show, here, the different methods used for optimizing the chosen kinematic architecture for the particular medical application. These studies lead to prototypes which are validated after medical experiments. This process of dimensional synthesis will be applied to other medical applications with different sets of specified constraints.
    出版者: Villeurbanne: EDP Sciences
    出版日期: 2014-01-01
    出處: Mechanics & industry : an international journal on mechanical sciences and engineering applications, 2014-01, Vol.15 (3), p.217-223
    資源來源: Alma/SFX Local Collection
    版權: AFM, EDP Sciences 2014
    版權: licence_http://creativecommons.org/publicdomain/zero
    識別號: ISSN: 2257-7777
    識別號: ISSN: 2257-7750
    識別號: EISSN: 2257-7750
    識別號: DOI: 10.1051/meca/2014022
    顯示於類別:[機械工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML14檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明