中大學術數位典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/109108
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94274/94274 (100%)
造访人次 : 82911161      在线人数 : 2234
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/109108


    题名: Ultrasound Elastography for Estimation of Regional Strain of Multilayered Hydrogels and Tissue-Engineered Cartilage
    作者: 鍾禎元;Chung, Chen-Yuan;Heebner, Joseph;Baskaran, Harihara;Welter, Jean F.;Mansour, Joseph M.
    贡献者: 工學院機械工程學系
    关键词: Biochemistry;Biological and Medical Physics;Biomechanics;Biomedical and Life Sciences;Biomedical Engineering and Bioengineering;Biomedicine;Biophysics;Bioreactors;Cartilage;Cartilage, Articular - diagnostic imaging;Cartilage, Articular - physiopathology;Cells, Cultured;Classical Mechanics;Construction;Elasticity Imaging Techniques;Finite Element Analysis;Finite element method;Humans;Hydrogels;Mechanical properties;Mesenchymal Stromal Cells;Reproducibility of Results;Strain;Stress, Mechanical;Tissue Engineering;Ultrasound
    日期: 2015-06-16
    上传时间: 2026-04-23 15:32:08 (UTC+8)
    出版者: Springer Netherlands;New York: Springer US
    摘要: 摘要: Tissue-engineered (TE) cartilage constructs tend to develop inhomogeneously, thus, to predict the mechanical performance of the tissue, conventional biomechanical testing, which yields average material properties, is of limited value. Rather, techniques for evaluating regional and depth-dependent properties of TE cartilage, preferably non-destructively, are required. The purpose of this study was to build upon our previous results and to investigate the feasibility of using ultrasound elastography to non-destructively assess the depth-dependent biomechanical characteristics of TE cartilage while in a sterile bioreactor. As a proof-of-concept, and to standardize an assessment protocol, a well-characterized three-layered hydrogel construct was used as a surrogate for TE cartilage, and was studied under controlled incremental compressions. The strain field of the construct predicted by elastography was then validated by comparison with a poroelastic finite-element analysis (FEA). On average, the differences between the strains predicted by elastography and the FEA were within 10%. Subsequently engineered cartilage tissue was evaluated in the same test fixture. Results from these examinations showed internal regions where the local strain was 1–2 orders of magnitude greater than that near the surface. These studies document the feasibility of using ultrasound to evaluate the mechanical behaviors of maturing TE constructs in a sterile environment.
    其他題名: Ann Biomed Eng
    出版者: New York: Springer US
    出版日期: 2015-12-01
    出處: Annals of biomedical engineering, 2015-12, Vol.43 (12), p.2991-3003
    版權: Biomedical Engineering Society 2015
    識別號: ISSN: 0090-6964
    識別號: EISSN: 1573-9686
    識別號: DOI: 10.1007/s10439-015-1356-x
    識別號: PMID: 26077987
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML15检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明