    Title: 扁平管平行流熱交換器於窗型空調機之應用研究
    Authors: 沈坤奇;Kun-Quin Shin
    Contributors: 機械工程研究所
    Keywords: 扁平管平行流蒸發器(PFE);扁平管平行流冷凝器 (PFC);扁平管平行流熱交換器(PFHE);室內空調系統(RAC);鰭管式熱交換器;扁平鋁擠型管
    Date: 2000-07-13
    Issue Date: 2009-09-21 11:34:07 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 本研究係探討扁平管平行流熱交換器於窗型空調機之應用研究,作者係採用本實驗室先前所發展出的扁平管平行流熱交換器最佳化程式設計為基礎,依據一市售5000 kcal/hr之窗型空調機的運轉條件,重新設計其所需之毛細管、扁平管平行流冷凝器及扁平管平行流蒸發器。先以扁平管平行流冷凝器更換窗型空調機之鰭管式冷凝器,並計算出新系統毛細管的長度,組裝測試,以驗證扁平管平行流冷凝器於窗型空調機之適用性,然後將鰭管式熱交換器全部以扁平管平行流蒸發器代替,並計算出新系統毛細管的長度,組裝測試,以驗證扁平管平行流熱交換器於窗型空調機之適用性。 由測試的結果得知,扁平管平行流冷凝器非常適用於窗型空調機上,扁平管平行流冷凝器約只需鰭管式熱交換器43%即可達到相同的熱負載;但扁平管平行流蒸發器因為凝結水無法順利排除,導致系統之性能下降,而使其優越的性能相對失色,假若可以解決排水的問題則扁平管平行流熱交換器非常適用於窗型空調機上,其不只提高效率、縮小產品體積,更可以減少資源的使用符合環保的需求
    Appears in Collections:[Graduate Institute of Mechanical Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明