中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/26604
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78852/78852 (100%)
造訪人次 : 37994238      線上人數 : 717
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/26604


    題名: Hemodynamic assessment of Carbomedics bileaflet heart valves by ultrasound: Studies in the aortic and mitral positions
    作者: Cape,EG;Sung,HW;Yoganathan,AP
    貢獻者: 化學工程與材料工程學系
    關鍵詞: SHEAR-STRESS MEASUREMENTS;INVITRO VELOCITY;VICINITY;PROSTHESES
    日期: 1996
    上傳時間: 2010-06-29 17:32:09 (UTC+8)
    出版者: 中央大學
    摘要: The bileaflet mechanical heart valve has become a]popular prosthesis for implantation in both the aortic and mitral positions and a recent design by Carbomedics has received widespread use, Noninvasive assessment of these valves by Doppler ultrasound is important in characterizing their normal performance and in assessing the course of dysfunction. This study addressed the hypothesis that Doppler predicted pressure drops will correlate with catheter pressure drops within a valve size and position, A subhypothesis is that the pressure drops agree, and we expect this subhypothesis to fail due to pressure recovery effects, In a well-controlled in vitro model it was shown that the combined effects of pressure recovery and neglecting proximal velocities resulted in overestimation of catheter pressure drops for Carbomedics bileaflet valves, Inclusion of the proximal velocity reduced overestimation of peak pressure drops for aortic and mitral valves to clinically acceptable levels, and removed overestimation of mean pressure drops, Without correction for proximal velocity, overestimation of mitral pressure drops was reduced to 3.32% when means were calculated, but mean aortic pressure drops still overestimated the catheter standard significantly, It is concluded that proximal velocities should be included in Bernoulli analysis of Carbomedics heart valves, If the proximal velocity is not available, mitral valves may be best assessed using mean pressure drops, while aortic valve Doppler data, peak or mean, should be interpreted with caution.
    關聯: ULTRASOUND IN MEDICINE AND BIOLOGY
    顯示於類別:[化學工程與材料工程研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML498檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明