NCU Institutional Repository:Item 987654321/26821

NCU Institutional Repository

Menu Search
查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/26821


    题名: Near infrared tomographic system based on high angular resolution mechanism - Design, calibration, and performance
    作者: Pan,MC;Chen,CH;Pan,MC;Shyr,YM
    贡献者: 生物醫學工程研究所
    关键词: DIFFUSE OPTICAL TOMOGRAPHY;IMAGE-RECONSTRUCTION;MODEL;INSTRUMENTATION;SCATTERING
    日期: 2009
    上传时间: 2010-06-29 17:54:22 (UTC+8)
    出版者: 中央大學
    摘要: This study aims at the design, implementation, and verification of a near infrared (NIR) diffuse optical tomography (DOT) electro-optical imaging system based on a measuring instrument with single rotating source/detector scanning mechanism and an image reconstruction scheme implemented on an off-line PC. The developed measurement instrument possesses a high degree of angular resolution and is operated in a continuous-intensity scheme to acquire output NIR intensity signals. In this paper, some considerations of this measuring instrument are investigated such as phantom preparation, temporal stability, and container influence, etc. Experimental trials were conducted using both homogeneous and heterogeneous phantoms made of high-scattering microspheres or Intralipid. In order to verify the developed imaging system with tomographic image reconstruction, the intensity was acquired from the heterogeneous Intralipid phantom using NIR light at 800 nm, where the homogenous background as the normal tissue is inserted with an inclusion as the tumor. For the comparison of heterogeneous phantoms with homogeneous phantoms, 1-D measured intensity signals indicate the angular position of the inclusion, especially for the case of the inclusion near the phantom boundary. Furthermore, promising results of corresponding optical-property images can be reconstructed with the measured intensities as inputs of the image reconstruction scheme. Obviously, the developed NIR DOT tomographic system has been successfully built upon the experimental, analytical, and computational work. (C) 2008 Elsevier Ltd. All rights reserved.
    關聯: MEASUREMENT
    显示于类别:[生物醫學工程研究所 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML950检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing
    DSpace Software Copyright © 2002-2004  MIT &  HP  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈