中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/28142
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78818/78818 (100%)
造访人次 : 34622611      在线人数 : 550
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/28142


    题名: Quantitative measurement of binding kinetics in sandwich assay using a fluorescence detection fiber-optic biosensor
    作者: Lin,CH;Chen,HY;Yu,CJ;Lu,PL;Hsieh,CH;Hsieh,BY;Chang,YF;Chou,C
    贡献者: 光電科學研究所
    关键词: POLY(METHYL METHACRYLATE);SURFACE;PROTEIN;SENSORS;IMMUNOSENSORS;ANTIGEN;PLASMA
    日期: 2009
    上传时间: 2010-06-29 19:42:24 (UTC+8)
    出版者: 中央大學
    摘要: Fiber-optic biosensors have been Studied intensively because they are very useful and important tools for monitoring biomolecular interactions. Here we describe a fluorescence detection fiber-optic biosensor (FD-FOB) using a sandwich assay to detect antibody-antigen interaction. In addition, the quantitative measurement of binding kinetics, including the association and dissociation rate constants for immunoglobulin G (IgG)/anti-mouse IgG, is achieved, indicating 0.38 x 10(6), M-1 s(-1) for k(a) and 3.15 x 10(-3) s(-1) for k(d). These constants are calculated from the fluorescence signals detected oil fiber surface only where the excited evanescent wave can be generated. Thus, a confined fluorescence-detecting region is achieved to specifically determine the binding kinetics at the vicinity of the interface between sensing materials and uncladded fiber surface. With this FD-FOB, the mathematical deduction and experimental verification of the binding kinetics in a sandwich immunoassay provide a theoretical basis for measuring rate constants and equilibrium dissociation constants. A further measurement to study the interaction between human heart-type fatty acid-binding protein and its antibody gave the calculated kinetic constants k(a), k(d), and K-D as 8.48 x 10(5) M-1 s(-1), 1.7 x 10(-3) s(-1), and 2.0 nM, respectively. Our study is the first attempt to establish a theoretical basis for the florescence-sensitive immunoassay using a sandwich format. Moreover, we demonstrate that the FD-FOB as a high-throughput biosensor can provide an alternative to the chip-based biosensors to study real-time biomolecular interaction. (c) 2008 Elsevier Inc. All rights reserved.
    關聯: ANALYTICAL BIOCHEMISTRY
    显示于类别:[光電科學研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML671检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明