English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42942750      線上人數 : 886
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/51024


    題名: Discrimination of Breast Cancer by Measuring Prostate-Specific Antigen Levels in Women's Serum
    作者: Chang,YF;Hung,SH;Lee,YJ;Chen,RC;Su,LC;Lai,CS;Chou,C
    貢獻者: 光電科學與工程學系
    關鍵詞: NIPPLE ASPIRATE FLUID;FLUORESCENCE FIBEROPTIC BIOSENSOR;GROWTH-FACTOR;EXPRESSION;IDENTIFICATION;POLYMORPHISMS;NANOPARTICLES;IMMUNOSENSOR;MAMMOGRAPHY;BENIGN
    日期: 2011
    上傳時間: 2012-03-27 18:15:55 (UTC+8)
    出版者: 國立中央大學
    摘要: Prostate-specific antigen (PSA) has been reported to be a potential biomarker of breast cancer. Serum PSA of normal women is around 1 pg/mL, which is usually undetectable by current assay methods; thus an ultrasensitive measurement of PSA expression in women's serum is necessary to distinguish normal from malignant breast diseases. To enhance the sensitivity of conventional immunoassay technology for the detection of PSA in sera, we adopted a localized surface plasmon coupled fluorescence fiber-optic biosensor, which combines a sandwich immunoassay with the localized surface plasmon technique, The concentration of total PSA (t-PSA) (from 0.1 to 1000 pg/mL) in phosphate-buffered saline solution and the normalized fluorescence signal exhibit a linear relationship where the correlation coefficient is 0.9574. In addition, the concentration of additional t-PSA in 10-fold-diluted healthly women's serum across a similar range was measured. The correlation coefficient for this measurement is 0.9142. In clinical serum samples, moreover, the experimental results of t-PSA detection show that both the mean value and median of normalized fluorescence signals in the breast cancer group (155.2 and 145.7, respectively) are higher than those in the noncancer group (46.6 and 37.1, respectively). We also exanfined the receiver operating characteristic curve for t-PSA, and the area under the curve (AUC) is estimated to be 0.9063, the AUC being used to measure the performance of a test to correctly identify diseased and nondiseased subjects.
    關聯: ANALYTICAL CHEMISTRY
    顯示於類別:[光電科學與工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML595檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明