中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/795
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 78937/78937 (100%)
Visitors : 39367891      Online Users : 450
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/795


    Title: 受損RC梁柱接頭補強之耐震成效評估;Seismic Assessment on Rehabilitation of Damaged RC Beam-Column Joints
    Authors: 黃士旗;Shih-Chi Huwang
    Contributors: 土木工程研究所
    Keywords: 鋼筋混凝土;梁柱接頭;補強;鋼纜線;Retrofit;Joint;Reinforced Concrete;Wire
    Date: 2003-06-30
    Issue Date: 2009-09-18 17:12:37 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 本實驗主要在探討已受損梁柱接頭採用鋼纜線混凝土擴柱補強方法的可行性,並由實驗結果中加以比較分析各試體的勁度、韌性、接頭剪力衰減及接頭混凝土剪應變等情形之差異 。 由實驗結果得知,鋼纜擴柱補強工法可以提高接頭剪力強度,使試體在接頭產生剪力破壞前先發生梁塑鉸破壞,但是補強成效仍不如預期,其主要原因為新舊混凝土面的剝離所導致。若是能在補強時,以植筋方式加強新舊面混凝土的握裹能力,則鋼纜擴柱補強工法應會發揮更大效果。 This experiment was mainly aimed at exploring feasibility of retrofitting damaged beam-column joint by wire concrete jacketing,and a discussion was made through the differences in stiffness, ductility, joint shear degradation between each retrofitted specimen。 From the experiment results,it was found that wire concrete jacketing scheme could improve the joint shear strength and make beam plastic hinge develop before joint shear failure。Howerver, the benefit of retrofitting does not come up to the target of the study because the split occurred in the interface between new and old concrete。It will improve the benefit of retrofitting by wire concrete jacketing if using anchoring method to prevent the split condition。
    Appears in Collections:[Graduate Institute of Civil Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明