English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78818/78818 (100%)
造訪人次 : 34775194      線上人數 : 510
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/92376


    題名: 以雷射測距儀製作古典吉他脈衝響應以應用於音色轉換;Impulse response generation of classical guitars using laser displacement sensor for tone transfer
    作者: 葉哲旭;YEH, CHE-HSU
    貢獻者: 光電科學與工程學系
    關鍵詞: 脈衝響應;轉移函數;古典吉他;麥克風;雷射測距儀;音色還原;impulse response;transfer function;microphone;classical guitar;laser displacement sensor;tone transformation
    日期: 2023-08-01
    上傳時間: 2023-10-04 15:50:34 (UTC+8)
    出版者: 國立中央大學
    摘要: 本研究主旨係在探討使用激發古典吉他後擷取的脈衝響應以及頻譜資料,製作出
    能將兩把古典吉他音色轉換的轉移函數。我們使用不同激發方法以及感測器來擷取古
    典吉他之脈衝響應以及頻譜資料,並使用頻譜相除法製做出能轉換音色的轉移函數,
    並對兩把古典吉他完成音色轉換。研究中使用了三種激發方法來擷取古典吉他的脈衝
    響應以及頻譜資料,分別是垂直面板撥絃法、氣球脈衝聲波法和喇叭播放白噪音法。
    透過比較這些方法,我們得出了以下結論。
    首先,比較了使用三種激發方法製作的轉移函數。結果顯示,這些方法都能成功
    激發出古典吉他的音孔共振頻率。但在觀察頻譜時,氣球脈衝聲波法和喇叭播放白噪
    音法出現了高頻噪聲過大和非目標還原音色的頻率峰值。由於垂直面板撥絃法的頻譜
    呈現較低的噪聲,也較適合用於激發古典吉他。
    其次,我們比較麥克風和雷射測距儀兩種感測器擷取的脈衝響應以及頻譜資料所
    製作的轉移函數。在同樣使用垂直面板撥絃加總法時,不論是麥克風擷取還是雷射測
    距儀製作的轉移函數,都能成功轉換古典吉他的音孔共振頻率峰值。但麥克風製作的
    轉移函數在還原音孔共振頻率的能量上相對較弱,而雷射測距儀製作的轉移函數能夠
    更好地還原音孔共振頻率。
    最後,我們使用互相關和重疊積分的結果,來評估麥克風和雷射測距儀所製作的
    轉移函數的音色還原效果。結果顯示,雷射測距儀所製作的轉移函數具有較高的互相
    關性和重疊積分值,這表明雷射測距儀所製作的轉移函數能夠更準確地還原古典吉他
    的音色。;The main objective of this study is to generate the transfer function capable of
    transforming the timbre of two classical guitars using the impulse responses captured after
    exciting the classical guitars. We employed different excitation methods and acoustic sensors
    to capture the impulse response of the classical guitars and to generate the transfer function
    for tone transformation between two guitars. Subsequently, we applied this transfer function
    to achieve tone transformation between the two classical guitars. Three excitation methods
    were used to capture the impulse response of the classical guitars: vertically plucking, balloon
    pulse sound wave, and white noise excitation by loudspeaker. Through a comparison of these
    methods, the following conclusions were drawn:
    Firstly, a comparison was made between the transfer functions produced using the three
    excitation methods. The results demonstrated that all these methods were successful in
    exciting the air resonant frequencies of the classical guitars. However, when observing the
    spectral data, the balloon pulse sound wave and white noise excitation by loudspeaker
    exhibited excessive high-frequency noise. The vertically plucking method, on the other hand,
    showed the lower noise levels and was more suitable for exciting the classical guitars.
    Secondly, we compared the transfer functions created from the impulse response
    captured by two different acoustic sensors: microphone and laser displacement sensor. The
    transfer function generated by both methods can successfully transform the air resonant
    frequency peaks of the classical guitars.
    Finally, we evaluated the tone restoration by the transfer functions produced by the
    microphone and the laser displacement sensor using the cross-correlation and the overlap
    integral. The results indicated that the transfer function generated by the laser displacement
    sensor exhibited higher cross-correlation and overlap integral values, suggesting that the use
    of the laser displacement sensor could restore more accurately the tone of the classical guitars.
    顯示於類別:[光電科學研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML24檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明