中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/94912
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42573169      線上人數 : 1699
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/94912


    題名: 光合色素分析儀與演算法開發;Photosynthesis pigment analyzer and algorithm development
    作者: 劉柏廷;Liu, Po-Ting
    貢獻者: 光電科學與工程學系
    關鍵詞: 智慧農業;物聯網;人工智能;光合色素;Smart Agriculture;IoT;AI;Photosynthetic Pigments
    日期: 2024-07-17
    上傳時間: 2024-10-09 15:36:56 (UTC+8)
    出版者: 國立中央大學
    摘要: 北美對於娛樂大麻與醫療大麻的推動,促使高經濟作物的種植盛行,進而帶動LED植物燈以及相關種植設備的發展與導入,加上極端天氣變化頻繁以及疫情因素,更推升高經濟作物的市場需求。本論文針對高經濟價值之食用植物為標的,希望結合感測器與AI演算法開發出智慧型非破壞手持式光合色素分析儀,以建立LED照射光譜與光合色素的關聯性。所開發出的感測裝置可應用於預估植物生長情況,提供植物工廠栽種者於種植時的參考。
    本研究使用番茄、萵苣、羽衣甘藍及皇宮菜為樣本。以HPLC量測結果作為基準,比對由手持式光合色素分析儀感測得到的葉綠素a、葉綠素b、β胡蘿蔔素、葉黃素四個光合色素之比例。感測所得的訊號,透過訊號特徵提取與AI模型的建立,提高非破壞手持式光合色素分析儀的精準度,根據實驗結果顯示,本儀器所量測到的各個經濟作物之數據與HPLC所量測到的結果差異皆在10%以內,證明以光合色素分析的方法測定植物營養素的準確率高達90%以上,符合原先之設計目標。
    ;The promotion of recreational and medical marijuana in North America has spurred the widespread cμLtivation of high-value crops, driving the development and adoption of LED grow lights and related equipment. Additionally, frequent extreme weather and the pandemic have further increased market demand for these crops. This paper focuses on developing a smart, non-destructive, handheld chlorophyll analyzer using sensors and AI algorithms to establish the correlation between LED light spectra and chlorophyll content. The device can estimate plant growth conditions, providing usefμL data for plant factory growers.
    Tomatoes, lettuce, kale, and choy sum were used as samples. HPLC measurements served as the benchmark, against which the proportions of chlorophyll a, chlorophyll b, beta-carotenoids, and xanthophylls measured by the handheld analyzer were compared. By extracting signal features and building AI models, the accuracy of the analyzer was improved. Experimental resμLts show that the data from the analyzer differed from HPLC resμLts by less than 10%, achieving an accuracy rate of over 90%, which meets the initial design goals.
    顯示於類別:[光電科學研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML19檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明