English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 81548502      線上人數 : 3250
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/99660


    題名: Earthquake response of reinforced segmental retaining walls backfilled with substantial percentage of fines
    作者: 王瑞斌;Ling, Hoe I;Leshchinsky, Dov;Mohri, Yoshiyuki;Wang, Jui-Pin
    貢獻者: 工學院土木工程學系
    關鍵詞: Applied sciences;Backfill;Buildings. Public works;Cohesion;Earthwork. Foundations. Retaining walls;Exact sciences and technology;Geotechnics;Reinforcement;Retaining walls;Sand;Seismic response;Soil suction;Structure-soil interaction;Technical Papers;Walls
    日期: 2012-01-01
    上傳時間: 2026-04-21 13:26:11 (UTC+8)
    出版者: American Society of Civil Engineers (ASCE);Reston, VA: American Society of Civil Engineers
    摘要: 摘要: AbstractThis paper reports on the seismic performance of three geosynthetic-reinforced segmental retaining wall systems backfilled with a silty sand mixture, using a shaking table excited by 1995 Kobe earthquake loadings. The preparation of the backfill mixture and its properties, the tested wall configurations, the reinforcement layouts and instrumentations, and the observed wall performance are described. Visual observations and test results indicate that walls having 0.4-m vertical reinforcement spacing, backfilled with soil containing a large percentage of fines, performed better than those having good-quality sandy soil under otherwise identical conditions. Vertical spacing of 0.8 m with removal of interlocking facing blocks in one of the walls did not lead to global collapse under repeated applications of the Kobe earthquake loadings. Only localized shear failure behind the top block layer was observed as the top facing blocks tended to topple. The good performance was attributable to apparent cohesion in the soil mixture stemming from soil matrix suction and true cohesion. Because this apparent cohesion is affected by the moisture content, its existence must be ensured by providing proper drainage to prevent seepage into the backfill. Considering the risk associated with the use of apparent cohesion, its exclusion from design is recommended.
    出版者: Reston, VA: American Society of Civil Engineers
    出版日期: 2012-08-01
    出處: Journal of geotechnical and geoenvironmental engineering, 2012-08, Vol.138 (8), p.934-944
    資源來源: American Society of Civil Engineers (ASCE) complete collection
    版權: 2012. American Society of Civil Engineers
    版權: 2014 INIST-CNRS
    識別號: ISSN: 1090-0241
    識別號: EISSN: 1943-5606
    識別號: DOI: 10.1061/(ASCE)GT.1943-5606.0000669
    顯示於類別:[土木工程學系 ] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML14檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明