English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94201/94201 (100%)
造訪人次 : 80415204      線上人數 : 191
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    NCU Institutional Repository > 理學院 > 化學學系 > 期刊論文 >  Item 987654321/101928


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/101928


    題名: Vortex-homogenized matrix solid-phase dispersion for the extraction of short chain chlorinated paraffins from indoor dust samples
    作者: 丁望賢;Chen, Yu-Hsuan;Chang, Chia-Yu;Ding, Wang-Hsien
    貢獻者: 理學院化學學系
    關鍵詞: Air Pollution, Indoor - analysis;Dust - analysis;gas chromatography;Gas Chromatography-Mass Spectrometry - methods;GC-ECNI-MS;glass;hexane;Hexanes - chemistry;Indoor dust;Limit of Detection;mass spectrometry;Methylene Chloride - chemistry;nitrogen;Paraffin - chemistry;Paraffin - isolation & purification;Short chain chlorinated paraffins;silica gel;Solid Phase Extraction;Vortex-assisted matrix solid-phase dispersion
    日期: 2016-11-11
    上傳時間: 2026-04-21 14:51:16 (UTC+8)
    出版者: Elsevier;Netherlands: Elsevier B.V
    摘要: 摘要: •VH-MSPD combined with GC-ECNI-MS was used for the first time to analyze SCCPs.•This method effectively determined SCCPs in indoor dust samples.•The method provides good precision and detection limits at the sub-μg/g level.•VH-MSPD does not require the acquisition of dedicated instrumentation. A simple and effective method for determining short chain chlorinated paraffins (SCCPs) in indoor dust is presented. The method employed a modified vortex-homogenized matrix solid-phase dispersion (VH-MSPD) prior to its detection by gas chromatography − electron-capture negative-ion mass spectrometry (GC-ECNI-MS) operating in the selected-ion-monitoring (SIM) mode. Under the best extraction conditions, 0.1-g of dust sample was dispersed with 0.1-g of silica gel by using vortex (2min) instead of using a mortar and pestle (3min). After that step, the blend was transferred to a glass column containing 3-g acidic silica gel, 2-g basic silica gel, and 2-g of deactivated silica gel, used as clean-up co-sorbents. Then, target analytes were eluted with 5mL of n-hexane/dichloromethane (2:1, v/v) mixture. The extract was evaporated to dryness under a gentle stream of nitrogen. The residue was then re-dissolved in n-hexane (10μL), and subjected to GC-ECNI-MS analysis. The limits of quantitation (LOQs) ranged from 0.06 to 0.25μg/g for each SCCP congener. Precision was less than 7% for both intra- and inter-day analysis. Trueness was above 89%, which was calculated by mean extraction recovery. The VH-MSPD combined with GC-ECNI-MS was successfully applied to quantitatively detect SCCPs from various indoor dust samples, and the concentrations ranged from 1.2 to 31.2μg/g.
    其他題名: J Chromatogr A
    出版者: Netherlands: Elsevier B.V
    出版日期: 2016-11-11
    出處: Journal of Chromatography A, 2016-11, Vol.1472, p.129-133
    版權: 2016 Elsevier B.V.
    版權: Copyright © 2016 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0021-9673
    識別號: ISSN: 1873-3778
    識別號: EISSN: 1873-3778
    識別號: DOI: 10.1016/j.chroma.2016.10.048
    識別號: PMID: 27773386
    顯示於類別:[化學學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML33檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明