題名:
Vortex-homogenized matrix solid-phase dispersion for the extraction of short chain chlorinated paraffins from indoor dust samples
作者:
丁望賢
;
Chen, Yu-Hsuan
;
Chang, Chia-Yu
;
Ding, Wang-Hsien
貢獻者:
理學院化學學系
關鍵詞:
Air Pollution, Indoor - analysis
;
Dust - analysis
;
gas chromatography
;
Gas Chromatography-Mass Spectrometry - methods
;
GC-ECNI-MS
;
glass
;
hexane
;
Hexanes - chemistry
;
Indoor dust
;
Limit of Detection
;
mass spectrometry
;
Methylene Chloride - chemistry
;
nitrogen
;
Paraffin - chemistry
;
Paraffin - isolation & purification
;
Short chain chlorinated paraffins
;
silica gel
;
Solid Phase Extraction
;
Vortex-assisted matrix solid-phase dispersion
日期:
2016-11-11
上傳時間:
2026-04-21 14:51:16 (UTC+8)
出版者:
Elsevier;Netherlands: Elsevier B.V
摘要:
摘要: •VH-MSPD combined with GC-ECNI-MS was used for the first time to analyze SCCPs.•This method effectively determined SCCPs in indoor dust samples.•The method provides good precision and detection limits at the sub-μg/g level.•VH-MSPD does not require the acquisition of dedicated instrumentation. A simple and effective method for determining short chain chlorinated paraffins (SCCPs) in indoor dust is presented. The method employed a modified vortex-homogenized matrix solid-phase dispersion (VH-MSPD) prior to its detection by gas chromatography − electron-capture negative-ion mass spectrometry (GC-ECNI-MS) operating in the selected-ion-monitoring (SIM) mode. Under the best extraction conditions, 0.1-g of dust sample was dispersed with 0.1-g of silica gel by using vortex (2min) instead of using a mortar and pestle (3min). After that step, the blend was transferred to a glass column containing 3-g acidic silica gel, 2-g basic silica gel, and 2-g of deactivated silica gel, used as clean-up co-sorbents. Then, target analytes were eluted with 5mL of n-hexane/dichloromethane (2:1, v/v) mixture. The extract was evaporated to dryness under a gentle stream of nitrogen. The residue was then re-dissolved in n-hexane (10μL), and subjected to GC-ECNI-MS analysis. The limits of quantitation (LOQs) ranged from 0.06 to 0.25μg/g for each SCCP congener. Precision was less than 7% for both intra- and inter-day analysis. Trueness was above 89%, which was calculated by mean extraction recovery. The VH-MSPD combined with GC-ECNI-MS was successfully applied to quantitatively detect SCCPs from various indoor dust samples, and the concentrations ranged from 1.2 to 31.2μg/g.
其他題名: J Chromatogr A
出版者: Netherlands: Elsevier B.V
出版日期: 2016-11-11
出處: Journal of Chromatography A, 2016-11, Vol.1472, p.129-133
版權: 2016 Elsevier B.V.
版權: Copyright © 2016 Elsevier B.V. All rights reserved.
識別號: ISSN: 0021-9673
識別號: ISSN: 1873-3778
識別號: EISSN: 1873-3778
識別號: DOI: 10.1016/j.chroma.2016.10.048
識別號: PMID: 27773386
顯示於類別:
[化學學系] 期刊論文
文件中的檔案:
檔案
描述
大小
格式
瀏覽次數
index.html
0Kb
HTML
33
檢視/開啟
在NCUIR中所有的資料項目都受到原著作權保護.
社群 sharing
::: Copyright National Central University. | 國立中央大學圖書館版權所有 |
收藏本站
|
設為首頁
| 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
DSpace Software
Copyright © 2002-2004
MIT
&
Hewlett-Packard
/
Enhanced by
NTU Library IR team
Copyright ©
-
隱私權政策聲明