參考文獻 |
[1] Prevention of blindness from diabetes mellitus, Report of WHO consulation in Geneva, Switzerland (2005), 9-11
[2] Homas R Moore, Diabetes Mellitus and Pregnancy. eMedicine. Version: Jan 27, (2005)
[3] Abdhish Bhavsar, Diabetic Retinopathy, 來源Medscape, 2010年12月21日取自http://emedicine.medscape.com/article/1225122-overview
[4] Definition and diagnosis of diabetes mellitus and intermediate hyperglycemia,World Health organization (2006)
[5] Sean F. Dinneen, Robert A. Rizza, Progression From Newly Acquired Impaired Fasting Glusose to Type 2 Diabetes, Diabetes Care. 30(2) (2007) 228-33.
[6] Huisman T.H., Martis E.A., Dozy A. Chromatography of hemoglobin types on carboxymethylcellulose. J. Lab. Clin. Med.52 (2): 312–27
[7] Rahbar S, Blumenfeld O, Ranney HM . "Studies of an unusual hemoglobin in patients with diabetes mellitus".Biochem. Biophys. Res. Commun. 36 (5): 838–43
[8] Diabetes Control and Complications Trial Research Group: The effect of intensive diabetes treatment on the development and progression of long-term complications in insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. N Engl J Med (1993) 329:978–986
[9] Limin Liu, Stefanie Hood, Yuping Wang, Robert Bezverkov, Chao Dou, Abhijit Datta, Chong Yuan, Direct enzymatic assay for %HbA1c in human whole blood samples, Clinical Biochemistry 41 (2008) 576 – 583
[10] David E. Goldstein, Randie R. Little, Rodney A. Lorenz, John I. Malone, David Nathan, Charles M. Peterson, David B. Sacks, Tests of Glycemia in Diabetes, Diabetes Care July 2004 vol. 27 no. 71761-1773, American Diabetes Association
[11] Seung Yeon Song, Hyun C. Yoon, Boronic acid-modified thin film interface for specific binding of glycated hemoglobin (HbA1c) and electrochemical biosensing, Sensors and Actuators B 140 (2009) 233–239
[12] D.M. Nathan, J. Kuenen, R. Borg, H. Zheng, D. Schoenfeld, R.J. Heine, Translating the A1C Assay Into Estimated Average Glucose Values, Diabetes Care 31 (2008) 1473–1478
[13] Serena Laschi, Marco Mascini, Planar electrochemical sensors for biomedical applications, Medical Engineering & Physics 28 (2006) 934–943
[14] 孔版印刷的發展, 來源:中華印刷通史, 2010年1月10日取自http://www.cgan.net/book/books/print/g-history/gb_9/23_7.htm
[15] 平面網印機產品圖, 來源:東遠精技股份有限公司, 2011年2月15日取自http://www.atma.com.tw/
[16] 平網曲面機產品圖, 來源:Skyhill明太網印儀器公司, 2011年2月15日取自http://www.ming-tai.com.tw/e-catalog/index.html
[17] 圓網印刷機產品圖, 來源:DGE德高機電企業集團2011年2月15日取自http://www.xadegao.com/jingtai.asp
[18] Pablo Fanjul-Bolado, David Hern´andez-Santos, Pedro Jos´e Lamas-Ardisana Alberto Mart´ın-Pern´ıa, Agust´ın Costa-Garc´ıa, Electrochemical characterization of screen-printed and conventional carbon paste electrodes, Electrochimica Acta 53 (2008) 3635–364
[19] E. Khaled, Gehad G. Mohamed, T. Awad, Disposal screen-printed carbon paste electrodes for the potentiometric titration of surfactants, Sensors and Actuators B 135 (2008) 74–80
[20] J. Wang, B. Tian,V.B. Nascimento, L. Angnes, Performance of screen –printed carbon electrodes fabricated from different carbon inks, Electrochimica Acta, Vol. 43, No. 23, (1998) 3459-3465
[21] D.D. Gornall, S.D. Collyer, Séamus P.J. Higson, Investigations into the use of screen-printed carbon electrodes as templates for electrochemical sensors and sonochemically fabricated microelectrode arrays, Sensors and Actuators B 141 (2009) 581–591
[22] F. Ghamouss, E. Luais, C. Thobie-Gautier, P.-Y. Tessier, M. Boujtita, Argon plasma treatment to enhance the electrochemical reactivity of screen-printed carbon surfaces, Electrochimica Acta 54 (2009) 3026–3032
[23] H. Wei, J.J. Sun, Yu Xie, C.G. Lin,Y.M. Wang, W.H. Yin, G.N. Chen, Enhanced electrochemical performance at screen-printed carbon electrodes by a new pretreating procedure, Analytica Chimica Acta 588 (2007) 297–303
[24] M. Pravda, C.O’Meara, G.G. Guilbault, Polishing of screen-printed electrodes improves IgG adsorption, Talanta 54 (2001) 887–892
[25] S.C. Wang, K.S. Chang, C.J. Yuan, Enhancement of electrochemical properties of screen-printed carbon electrodes by oxygen plasma treatment, Electrochimica Acta 54 (2009) 4937–4943
[26] M.D. Osborne , B.J. Seddon , R.A.W. Dryfe , G. Lagger , U. Loyal1 , H. Schifer , H.H. Girault , Excimer laser-induced electrochemical activity in carbon ink films, Journal of Electroanalytical Chemistry 417 (1996) 5-15
[27] W.Y. Su, S.M. Wang, S.H. Cheng, Electrochemically pretreated screen-printed carbon electrodes for the simultaneous determination of aminophenol isomers, Journal of Electroanalytical Chemistry 651 (2011) 166–172
[28] F. Ghamouss, P.-Y. Tessier, M.A. Djouadi, M.-P. Besland, M. Boujtita, Examination of the electrochemical reactivity of screen printed carbon electrode treated by radio-frequency argon plasma, Electrochemistry Communications 9 (2007) 1798–1804
[29] E. Crouch, D.C. Cowell, S. Hoskins, R.W. Pittson, J. P. Hart, A novel disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink, Biosensors and Bioelectronics 21 (2005) 712–718
[30] Pedro José Lamas-Ardisana, Alberto Martín-Pernía and Agustín Costa-García, Pablo Fanjul-Bolado, David Hernández-Santos, Electrochemical characterization of screen-printed and conventional carbon paste electrodes, Electrochimica Acta 53 (2008) 3635–3642
[31] F. Ghamouss, P.-Y. Tessier, A. Djouadi, M.-P. Besland, M. Boujtita, Screen-printed carbon electrode modified on its surface with amorphous carbon nitride thin film: Electrochemical and morphological study, Electrochimica Acta 52 (2007) 5053–5061
[32] 吳浩青, 李永舫, 電化學動力學, 科技圖書出版社, 2001
[33] P. Tamiasso-Martinhon, H. Cachet, C. Debiemme-Chouvy, C. Deslouis, Thin films of amorphous nitrogenated carbon a-CNx, Electrochimica Acta 53 (2008) 5752–5759
[34] S. Hleli, C. Martelet,, A. Abdelghani, F. Bessueille, A. Errachid, J. Samitier,H.C.W. Hays, P.A. Millner, N. Burais, N. Jaffrezic-Renault, An immunosensor for haemoglobin based on impedimetric properties of a new mixed self-assembled monolayer, Materials Science and Engineering C 26 (2006) 322 – 327
[35] T. Balkenhohl, F. Lisdat, Screen-printed electrodes as impedimetric immunosensors for the detection of anti-transglutaminase antibodies in human sera, Analytica Chimica Acta 597 (2007) 50–57
[36] Cesar Fernandez-Sanchez, Calum J. McNeil, Keith Rawson, Electrochemical impedance spectroscopy studies of polymer degradation: application to biosensor development, Trends in Analytical Chemistry, Vol. 24, No. 1, 2005
[37] David A. Harrington, P. van den Driessche, Mechanism and equivalent circuits in electrochemical impedance spectroscopy, Electrochimica Acta (2011)
[38] CMS300 Electrochemical System Operator’s Manual, Gamery Instruments, Inc., USA, 1993.
[39] Ivanildo Luiz de Mattos, Lo Gorton , Tautgirdas Ruzgas, Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes, Biosensors and Bioelectronics 18 (2003) 193-200
[40] Gehad G. Mohamed, Tamer Awad Ali, M.F. El-Shahat, A.M. Al-Sabagh,M.A. Migahed, Elmorsy KhaledD, Potentiometric determination of cetylpyridinium chloride using a new type of screen-printed ion selective electrodes, Analytica Chimica Acta 673 (2010) 79–87
[41] J.P. Hart, A.K. Abass, D. Cowell, Development of disposable amperometric sulfur dioxide biosensors based on screen printed electrodes, Biosensors & Bioelectronics 17 (2002) 389–394
[42] K.C. Honeychurch, J.P. Hart, P.R.J. Pritchard, S.J. Hawkins, N.M. Ratcliffe, Development of an electrochemical assay for 2,6-dinitrotoluene, based on a screen-printed carbon electrode, and its potential application in bioanalysis, occupational and public health, Biosensors and Bioelectronics 19 (2003) 305-312
[43] Belen Bello Rodriguez, John A. Bolbot, Ibtisam E. Tothill, Development of urease and glutamic dehydrogenase amperometric assay for heavy metals screening in polluted samples, Biosensors and Bioelectronics 19 (2004) 1157–1167
[44] L. Micheli, R. Grecco, M. Badea, D. Moscone, G. Palleschi, An electrochemical immunosensor for aflatoxin M1 determination in milk using screen-printed electrodes, Biosensors and Bioelectronics 21 (2005) 588–596
[45] Jie Wu, Jinhai Tang, Zong Dai, Feng Yan, Huangxian Ju, Nabil El Murr, A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen, Biosensors and Bioelectronics 22 (2006) 102–108
[46] Guido Carpini, Fausto Lucarelli, Giovanna Marrazza, Marco Mascin, Oligonucleotide-modified screen-printed gold electrodes for enzyme-amplified sensing of nucleic acids, Biosensors and Bioelectronics 20 (2004) 167–175
[47] Lam Dai Tran, Binh Hai Nguyen, Nguyen Van Hieu, Hoang Vinh Tran,Huy Le Nguyen, Phuc Xuan Nguyen, Electrochemical detection of short HIV sequences on chitosan/Fe3O4 nanoparticle based screen printed electrodes, Materials Science and Engineering C 31 (2011) 477–485
[48] W. Laureyn, D. Nelis, P. Van Gerwen, K. Baert, L. Hermans, R. Magnee, J.-J. Pireaux, G. Maes, Nanoscaled interdigitated titanium electrodes for impedimetric biosensing, Sensors and Actuators B 68 (2000) 360-370
[49] T. Houssin, J. Follet, A. Follet, E. Dei-Cas, V. Senez, Label-free analysis of water-polluting parasite by electrochemical impedance spectroscopy, Biosensors and Bioelectronics 25 (2010) 1122–1129
[50] P.V. Gerwen, W. Laureyn, W. Laureys, G. Huyberechts, Maaike Op De Beeck, Kris Baert, Jan Suls, Willy Sansen, P. Jacobs, Lou Hermans, Robert Mertens, Nanoscaled interdigitated electrode arrays for biochemical sensors, Sensors and Actuators B 49 (1998) 73–80
[51] Enrique Valera, Javier Ram´on-Azc´on, ´Angel Rodr´ıguez, Luis M. Casta˜ner, F.-J. S´anchez, M.-P. Marco, Impedimetric immunosensor for atrazine detection using interdigitated μ-electrodes (IDμE’s), Sensors and Actuators B 125 (2007) 526–537
[52] W. Laureyn, D. Nelis, P. Van Gerwen, K. Baert, L. Hermans, R. Magnee , J.-J. Pireaux, G. Maes, Nanoscaled interdigitated titanium electrodes for impedimetric biosensing, Sensors and Actuators B 68 2000 360–370
[53] Angel Rodr´ıguez, Enrique Valera, Javier Ramon-Azc´on´, F.-J. Sanchez, M.-P. Marco, Luis M. Castaner, Single frequency impedimetric immunosensor for atrazine detection, Sensors and Actuators B 129 (2008) 921–928
[54] Enrique Valera, David Muñiz, Ángel Rodríguez, Fabrication of flexible interdigitated l-electrodes (FIDlEs) for the development of a conductimetric immunosensor for atrazine detection based on antibodies labelled with gold nanoparticles, Microelectronic Engineering 87 (2010) 167–173
[55] Analog Devices AD5933data sheet, Analog Devices
[56] A Technical Tutorialon Digital Signal Synthesis data sheet, Analog Devices
[57] 戴佳, 戴衛恆, 8051單晶片C語言應用程式設計實力詳解, 松岡電腦圖書有限公司, 2007
[58] 鄭錦聰, 莊鎮家, MATLAB程式設計實務, 全華圖書股份有限公司, 2009
[59] Attila Vig, Xavier Mu noz-Berbel, Antonio Radoi, Montserrat Cortina-Puig, Jean-Louis Marty, Characterization of the gold-catalyzed deposition of silver on graphite screen-printed electrodes and their application to the development of impedimetric immunosensors, Talanta 80 (2009) 942–946
[60] Hong Cai, Thomas Ming-Hung Lee, I-Ming Hsing, Label-free protein recognition using an aptamer-based impedance measurement assay, Sensors and Actuators B 114 (2006) 433–437
[61] Jung A Lee, Seongpil Hwang, Juhyoun Kwak, Se Il Park, Seung S. Lee, Kwang-Cheol Lee, An electrochemical impedance biosensor with aptamer-modified pyrolyzed carbon electrode for label-free protein detection, Sensors and Actuators B 129 (2008) 372–379
[62] Zhiwei Zou, Junhai Kai, Michael J. Rust, Jungyoup Han, Chong H. Ahn, Functionalized nano interdigitated electrodes arrays on polymer with integrated microfluidics for direct bio-affinity sensing using impedimetric measurement, Sensors and Actuators A 136 (2007) 518–526
[63] Haiying Yu, HermannBerg, Electrofusion of protoplasts modified by protein adsorption, Bioelectrochemistry and Bioenergetics 44 1998 233–236
[64] Electrochemical detection of HbA1c, a maker for diabetes,using a flow immunoassay system, Tsuyoshi Tanaka , Shoko Tsukube , Kojiro Izawa , Mina Okochi , Tae-Kyu Limb, Shugo Watanabe , Manabu Harada , Tadashi Matsunaga, Biosensors and Bioelectronics 22 (2007) 2051–2056
[65] J. Wang, Analytical Electrochemistry 3rd edition, John Wiley & Sons, 2006
[66] Phosphate Buffer Saline E404-100TABS技術資料, aMResco
[67] ITK碳漿SC-1010 技術資料, 愛迪克科技股份有限公司
[68] Carbon Graphite Ink GWENT-C2050517D1技術資料, Gwent Group
[69] Carbon Graphite Ink GWENT-C2030519P4技術資料, Gwent Group
[70] ZAHNER IM6-ex電化學量測儀操作手冊, ZAHNER
[71] HIOKI 3532-50 LCR HiTESTER阻抗分析儀操作手冊, HIOKI
|