博碩士論文 107624602 完整後設資料紀錄

DC 欄位 語言
DC.contributor應用地質研究所zh_TW
DC.creator團氏青翠zh_TW
DC.creatorDoan Thi Thanh thuyen_US
dc.date.accessioned2021-1-11T07:39:07Z
dc.date.available2021-1-11T07:39:07Z
dc.date.issued2021
dc.identifier.urihttp://ir.lib.ncu.edu.tw:444/thesis/view_etd.asp?URN=107624602
dc.contributor.department應用地質研究所zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract良好的地下水資源管理主要依靠對含水層水文地質特性的理解, 如含水層 水力傳導率( K) 等參數。一般而言,此類參數須透過不同水力試驗來推估。 常 見的含水層的水力傳導率值推估方法如抽水試驗及水力掃描方法, 這類方法有 其限制,例如因為數據解決方案和覆蓋範圍中存在許多不匹配的情況, 所求參 數會有非唯一性之問題。 近年來,使用分佈式溫度感測( DTS)技術進行的示踪劑測試開闢了一種替 代其他參數推估的方法。本研究的目的是利用溫度作為示蹤劑,結合水力掃描 方法之概念,以推估含水層中水文地質參數分布狀況。 在這項研究中, 利用沙 箱實驗比較溫度試驗和水力掃描測試所獲得的水力特性值,透過VSAFT2分析, 以評估含水層的參數分布推估狀況。 結果顯示,模擬水頭明顯高於注入口處的實測水頭值。 根據溫度試驗分佈, 沙箱中的溫度受低溫水的影響很大。此外,溫度數據的反推估含水層非均質性 有良好的辨識率,而水頭數據的反推估分辨率較低,推估結果中, 熱導率的相 關性高於水力導率的相關性, 分別為 0.84 和 0.97。 總而言之, 本研究結果為將 溫度示踪劑測試應用到實際案例中提供了良好的示範。zh_TW
dc.description.abstractGroundwater resources management has substantially relied on an understanding of hydrological properties. Important properties such as hydraulic conductivity (K) are estimated with hydraulic head collected from hydraulic tests. Conventional approaches to obtain the hydraulic conductivity value for aquifers rely on hydraulic tomography survey with several drawbacks such as non-unique since many mismatches exist in the data solution and coverage. In recent years, tracer test using Distributed Temperature Sensing (DTS) technology opens up the approach of replacing additional test data with the estimation of hydraulic properties. The purpose of this research is to test and compare the hydraulic properties values measured by temperature and head in sandbox experiment. In the study, VSAFT2 software is applied to the cross-hole hydraulic and heat experiments for the estimation of aquifer properties. The results showed that the simulated head was considerably higher than the measured head values at the injection ports. Based on the temperature distribution, the study also indicates that the temperature in the sandbox is significantly influenced by the low-temperature water. Furthermore, the results showed that the inversion of temperature data resulted in a smoothed reconstruction of aquifer heterogeneity while head data inversion leads to lower resolution estimation. More details, the correlation from thermal conductivity is higher than hydraulic conductivity are 0.84, and 0.97 respectively. To conclude, the result of thermal conductivity presents benefits and potential to deploy the tracer test using DTS into practical case.en_US
DC.subject熱力和水力掃描調查zh_TW
DC.subject沙箱實驗,zh_TW
DC.subject水力傳導率zh_TW
DC.subject熱傳導率zh_TW
DC.subjectVSAFT2zh_TW
DC.subjectheat and hydraulic tomography surveysen_US
DC.subjectsandbox experimenten_US
DC.subjecthydraulic conductivityen_US
DC.subjectthermal conductivityen_US
DC.subjectVSAFT2en_US
DC.titleEstimations of aquifer properties by using cross-hole hydraulic and heat tomography surveys in a two- dimensional profile sandboxen_US
dc.language.isoen_USen_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明