博碩士論文 90322002 完整後設資料紀錄

DC 欄位 語言
DC.contributor土木工程學系zh_TW
DC.creator黃士旗zh_TW
DC.creatorShih-Chi Huwangen_US
dc.date.accessioned2003-7-15T07:39:07Z
dc.date.available2003-7-15T07:39:07Z
dc.date.issued2003
dc.identifier.urihttp://ir.lib.ncu.edu.tw:444/thesis/view_etd.asp?URN=90322002
dc.contributor.department土木工程學系zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract本實驗主要在探討已受損梁柱接頭採用鋼纜線混凝土擴柱補強方法的可行性,並由實驗結果中加以比較分析各試體的勁度、韌性、接頭剪力衰減及接頭混凝土剪應變等情形之差異 。 由實驗結果得知,鋼纜擴柱補強工法可以提高接頭剪力強度,使試體在接頭產生剪力破壞前先發生梁塑鉸破壞,但是補強成效仍不如預期,其主要原因為新舊混凝土面的剝離所導致。若是能在補強時,以植筋方式加強新舊面混凝土的握裹能力,則鋼纜擴柱補強工法應會發揮更大效果。zh_TW
dc.description.abstractThis experiment was mainly aimed at exploring feasibility of retrofitting damaged beam-column joint by wire concrete jacketing,and a discussion was made through the differences in stiffness, ductility, joint shear degradation between each retrofitted specimen。 From the experiment results,it was found that wire concrete jacketing scheme could improve the joint shear strength and make beam plastic hinge develop before joint shear failure。Howerver, the benefit of retrofitting does not come up to the target of the study because the split occurred in the interface between new and old concrete。It will improve the benefit of retrofitting by wire concrete jacketing if using anchoring method to prevent the split condition。en_US
DC.subject鋼筋混凝土zh_TW
DC.subject梁柱接頭zh_TW
DC.subject補強zh_TW
DC.subject鋼纜線zh_TW
DC.subjectRetrofiten_US
DC.subjectJointen_US
DC.subjectReinforced Concreteen_US
DC.subjectWireen_US
DC.title受損RC梁柱接頭補強之耐震成效評估zh_TW
dc.language.isozh-TWzh-TW
DC.titleSeismic Assessment on Rehabilitation of Damaged RC Beam-Column Jointsen_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明