參考文獻 |
參考文獻
[1] 李家同,「為工具機及機械手臂設計的精密量測系統」,機械工業雜誌,452,2020年,2-4頁。
[2] C. S. Liu, J. J. Lai, and Y. T. Luo, "Design of a measurement system for six-degree-of-freedom geometric errors of a linear guide of a machine tool," Sensors 19(1), 5 (2018).
[3] Y. T. Chen, W. C. Lin, and C. S. Liu, "Design and experimental verification of novel six-degree-of freedom geometric error measurement system for linear stage," Opt. Lasers Eng. 92, 94 (2017).
[4] S. Xiang and Y. Altintas, "Modeling and compensation of volumetric errors for five-axis machine tools," Int. J. Mach. Tools Manuf. 101, 65 (2016).
[5] J. Yuan and X. Long, "CCD-area-based autocollimator for precision small-angle measurement," Rev. Sci. Instrum. 74(3), 1362 (2003).
[6] S. Wang, R. Ma, F. Cao, L. Luo, and X. Li, "A Review: High-Precision Angle Measurement Technologies," Sensors 24(6), 1755 (2024).
[7] S. Zhou, V. Le, Q. Mi, and G. Wu, "Grating-corner-cube-based roll angle sensor," Sensors 20(19), 5524 (2020).
[8] W. Ren, J. Cui, and J. Tan, "A novel enhanced roll-angle measurement system based on a transmission grating autocollimator," IEEE Access 7, 2169 (2019).
[9] T. Jin, G. Xia, W. Hou, Y. Le, and S. Han, "High resolution and stability roll angle measurement method for precision linear displacement stages," Rev. Sci. Instrum. 88(2), 023102 (2017).
[10] W. Dwi Astuti, H. Matsukuma, M. Nakao, K. Li, Y. Shimizu, and W. Gao, "An optical frequency domain angle measurement method based on second harmonic generation," Sensors 21(2), 670 (2021).
[11] J. Y. Lin and Y. C. Liao, "Small-angle measurement with highly sensitive total-internal-reflection heterodyne interferometer," Appl. Opt. 53(9), 1903 (2014).
[12] Y. Liu, C. Kuang, and Y. Ku, "Small angle measurement method based on the total internal multi-reflection," Opt. Laser Technol. 44(5), 1346 (2012).
[13] X. Liang, J. Lin, T. Wu, L. Yang, Y. Wang, Y. Liu, and J. Zhu, "Absolute angular measurement with optical frequency comb using a dispersive interferometry," Opt. Express 28(24), 36095 (2020).
[14] Y. T. Hsu and H. L. Hsieh, "Development of a coplanar grating interferometer for displacement and angle measurements," Proc. SPIE 12137, 22 (2022).
[15] Y. Zhu, S. Liu, C. Kuang, S. Li, and X. Liu, "Roll angle measurement based on common path compensation principle," Opt. Lasers Eng. 67, 66 (2015).
[16] J. Qi, Z. Wang, J. Huang, Q. Wang, and J. Gao, "Heterodyne interferometer with two parallel-polarized input beams for high-resolution roll angle measurement," Opt. Express 27(10), 13820 (2019).
[17] S. Wu, J. Yang, W. Li, F. Wu, and M. Dong, "Precision roll angle measurement based on digital speckle pattern interferometry," Meas. Sci. Technol. 30(4), 045005 (2019).
[18] W. Ren, J. Cui, and J. Tan, "A three-dimensional small angle measurement system based on autocollimation method," Rev. Sci. Instrum. 93(5), 055102 (2022).
[19] Y. Guo, H. Cheng, Y. Wen, and Y. Feng, "Three-degree-of-freedom autocollimator based on a combined target reflector," Appl. Opt. 59(8), 2262 (2020).
[20] J. Y. Lee, C. T. Hsu, S. H. Chang, and W. Y. Chen, "Dual beam polarization interferometry for roll angular displacement measurement," Measurement 222, 113571 (2023).
[21] E. Hecht, Optics, 5e Pearson Education India (2002).
[22] W. H. Chen, W. K. Kuo, S. L. Huang, Y. T. Huang, and H. Z. Cheng, "On-wafer 2D etectric-field-vector mapping using one-beam electro-optic probing technique," Conference on Lasers and Electro-Optics, Optica Publishing Group (2000).
[23] 陳林裕,「雙折射外差干涉術之角度量測及定位技術開發」,國立中央大學,碩士論文,民國 103 年。
[24] 趙凱華,鍾錫華,「光學」,儒林圖書有限公司,民國 86 年。
[25] H. L. Hsieh, J. Y. Lee, L. Y. Chen, and Y. Yang, "Development of an angular displacement measurement technique through birefringence heterodyne interferometry," Opt. Express 24(7), 6802 (2016).
[26] A. Yariv and P. Yeh, "Optical Waves in Crystals," John Wiley, 1st Edition. (2003).
[27] M. Zou, "Analyses of Jones matrix of polarized-light interference," Coll. Phys. 27(10), 10 (2008).
[28] J. Y. Lee, T. K. Chou, and H. C. Shih, "Polarization-interferometric surface- plasmonresonance imaging system," Opt. Lett. 33(5), 434 (2008).
[29] 陳柏翰,「四步移相解相位系統應用於光柵耦合表面電漿共振」,國立中央大學,碩士論文,民國 102 年。
[30] 偏振相機 BFS-U3-51S5P-C (Edmund Optics).
https://www.edmundoptics.com.tw/p/bfs-u3-51s5p-c-usb3-blackflyreg-s-polarization-camera/41357/
[31] 宋瑋益,「基於雙折射偏振干涉術之滾轉角量測技術」,國立中央大學,碩士論文,民國110年。
[32] 許敬澤,「雙光束偏振干涉術應用於滾轉角位移量測」,國立中央大學,碩士論文,民國 111 年。
[33] J. Y. Lee, W. Y. Sung, and C. T. Hsu, "Dynamic range enhancement of the roll angle displacement measurement with birefringence using a polarization camera," Appl. Opt. 60(29), 9110 (2021).
[34] K. Itoh, "Analysis of the phase unwrapping algorithm," Appl. Opt. 21(14), 2470 (1982).
[35] 電控旋轉平台 PRM1-Z8 (Thorlabs).
https://www.thorlabs.us/thorProduct.cfm?partNumber=PRM1Z8#ad-image-0
[36] 蕭宇傑,「雙共交顯微鏡用於物體厚度量測」,國立中央大學,碩士論文,民國107年。
[37] Thorlabs APT software.
https://www.thorlabs.com/software_pages/ViewSoftwarePage.cfm?Code=Motion_Contr ol&viewtab=1
[38] 偏振相機感光元件 (Polarization Image Sensor-Sony IMX250MYR).
https://www.sony-semicon.co.jp/e/products/IS/industry/product/polarization.html
[39] 偏振相機計算單元組成圖
http://thinklucid.cn/tech-briefs/polarization-explained-sony-polarized-sensor/
[40] R. J. Moffat, “Describing the uncertainties in experimental results, " Exp. Therm. Fluid Sci. 1(1), 3 (1988).
[41] M. Nehir, C. Frank, S. Aßmann, and E. P. Achterberg, "Improving optical measurements: non-linearity compensation of compact charge-coupled device (CCD) spectrometers," Sensors 19(12), 2833 (2019). |